Fluke a3001 FC Wireless iFlex AC Current Clamp Kit

£368.95

£442.74

SKU
FLU/FLK-A3001FC KIT
  • Everything you'll need to create a wireless network for measuring AC current
  • Continuity, resistance, diode, capacitance and frequency measurements
  • Probe bends around even the most difficult of conductors
  • Measurements of AC current up to 2500A
pdf
(Size: 146.8 KB)
pdf
(Size: 2.8 MB)
More Information
Warranty1 year
Price MatchNo

Fluke a3001 FC Wireless iFlex AC Current Clamp Kit 

Connect the a3001 FC Wireless AC Current Module and flexible current probe to your test point, and view the results up to 20 metres away on the 3000 FC Wireless Digital Multimeter.

You'll save time, with less run-around collecting multiple measurements.  Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect modules as a system for multiple measurements.

From short distances, you can even view readings from modules through closed electrical  Fluke a3001 FC Wireless iFlex AC Current Clamp Kit provides measurement of many common electrical parameters.

Fluke 3000 FC Wireless Multimeter:

  • AC/DC voltage measurements
  • AC/DC current measurements
  • Continuity, resistance, diode, capacitance and frequency measurements
  • MIN/MAX recording
  • CAT III 1000V and CAT IV 600V safety rated
  • IP54 ingress protection
  • Wireless connectivity with other Fluke FC series compatible instruments/devices


Fluke a3001 FC Wireless iFlex AC:

  • Measurements of AC current up to 2500A
  • Suitable for use individually as a clamp meter or can wirelessly interface with other Fluke FC testing tools
  • Logging function stores up to 65000 measurements directly on the module
  • Inrush function
  • Bendable probe

Fluke 3000 FC Wireless Multimeter Specifications:

AC Voltage
RangeResolutionAccuracy 
  45Hz to 500Hz500Hz to 1KHz
600.0mV0.1mV1.0% + 32.0% + 3
6.000V0.001V
60.00V0.01V
600.0V0.1V
1000V1V
Note

All AC voltage ranges are specified from 1% of range to 100% of range.
Crest factor of ≤ 3 at full scale up to 500V, decreasing linearly to crest factor < 1.5 at 1000V
For non sinusoidal waveforms, add ± (2% of reading + 2% of full scale) typical, for crest factor up to 3.
Do not exceed 10V Hz

DC Voltage, Continuity, Resistance, Diode Test and Capacitance
FunctionRangeResolutionAccuracy
mV600.0mV0.1mV0.09% + 2
V6.000V0.001V0.09% + 2
60.00V0.01V
600.0V0.1V
1000V1V0.15% + 2
Ω600.0Ω0.1Ω0.5% + 1
6.000kΩ0.001kΩ
60.00kΩ0.01kΩ
60.00kΩ0.1kΩ
600.0kΩ0.001MΩ
50.00MΩ0.01MΩ1.5% + 3
Diode Test2.000V0.001V1% + 2
μF1000nF1nF10% typical
10.00μF0.01μF
100.0μF0.1μF
9999μF1μF
NoteIn the 9999μF range for measurements to 1000μF, the measurement accuracy is 1.2% + 2
AC and DC Current
FunctionRangeResolutionAccuracy
mA AC (45Hz to 1KHz)60.00mA0.01mA1.5% + 3
400.0mA 
mA DC60.00mA0.01mA0.5% + 3
 400.0mA0.1mA
NoteAll AC current ranges are specified from 5% of range to 100% of range
Input burden voltage (typical): 400mA input 2mV/mA
400.0mA accuracy specified up to 600mA overload
Frequency
RangeResolutionAccuracy
99.99Hz0.01Hz0.1% + 1
999.9Hz0.1Hz
9.999kHz0.001Hz
99.99kHz0.01kHz
Input Characteristics
FunctionOverload ProtectionInput Impedance (Nominal)Common Mode Rejection Ratio (1kΩ Unbalance)Normal Mode Rejection
1100V rms>10MΩ < 100pF> 120 dB at dc, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100V rms>10MΩ < 100pF> 60 dB, dc to 60 Hz 
1100V rms>10MΩ < 100pF> 120 dB at dc, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
Open Circuit Test VoltageFull Scale VoltageTypical Short Circuit Current
1100V rms<2.7V DCTo 6MΩ: <0.7VDC
50MΩ: <0.9V DC
<350mA
1100V rms<2.7V DC2.000V DC<1.1mA
FunctionOverload Protection Overload
mAFused, 44/100A, 1000V FAST Fuse  600mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording
FunctionAccuracy
DC FunctionsThe specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration.
AC FunctionsThe specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration.
General Specifications
Maximum Voltage Between Any Terminal and Earth Ground1000V DC or AC RMS
Ω Fuse Protection From A Inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate: 4/sec
Votls, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery Type3 x AA alkaline batteries, NEDA 15A IEC LR6
Battery Life250 hours maximum
RF Communications2.4GHZ ISM Band
RF Communication RangeOpen air, unobstructed: Up to 20m
Obstructed, sheetrock wall: Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
TemperatureOperating: -10 °C to 50 °C
Storage: -40 °C to 60 °C
Temperature Coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Relative Humidity0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C)
AltitudeOperating: 2,000 m
Storage: 12,000 m
Electromagnetic Compatability EMI, RFI, EMC, RFEN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249,
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety ComplianceANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
CertificationsCSA, FCC, CE
Ingress Protection (IP) RatingIP54
Pollution Degree2
Size (H x W x L)4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight340g (12oz)

 

Fluke a3001 FC Technical Specifications:

Range0.5A to 2500A AC
Resolution0.1A
Accuracy3% ± 5 digits (5Hz to 500Hz)
Crest Factor (50Hz/60Hz)3.0 at 1100A
2.5 at 1400A
1.42 at 2500A
add 2% for C.F > 2
LCD w/Backlight3 1/2 digits
Log Rate/Interval1 sec minimum/adjustable by PC or front panel
Battery Type2 AA, NEDA 15A, IEC LR6
Battery Life400 hours
MemoryRecord up to 65000 readings
RF Communications2.4GHZ ISM band
RF Communication RangeOpen Air, Unobsctructed: Up to 20m
Obstructed, Sheetrock Wall: Up to 6.5m
Obstructed, Concrete Wall or Steel Electrical Enclosure: Up to 3.5m
Operating Temperature-10 to 50°C
Storage Temperature-40 to 60°C
Temperature CoefficientAdd 0.1X (specified accuracy) / °C (<18°C or >28°C)
Operating Humidity90% at 35°C
75% at 40°C
45% at 50°C
AltitudeOperating: 2000m
Storage: 12000m
EMCEN 61326-2006
Safety ComplianceIEC 61010-1, 600V CAT IV/ 1000V CAT III, 3rd edition
Safety RatingCAT IV 600V, CAT III 1000V
CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) RatingIP42
Pollution Degree2
Jaw Opening25.4cm (10in) coil
Size (H x W x D)16.5cm x 6.35cm x 1.4cm (6.5in x 2.5in x 1.4in)
Weight.22kg (8 oz)

 

What's Included?

  • Fluke 3000 FC Series Wireless Digital Multimeter
  • Fluke a3001 FC Wireless iFlex AC Current Module
  • TL175 Test Leads
  • AC175 Alligator Clips
  • iFlex i2500-10 Flexible Current Probe
Write Your Own Review