  • Flue Gas & Ambient Air Analyser with Direct CO & CO2 Measurement.
  • Combustion Analysis, Direct CO2 Measurement & Measure CO, CO2 & Ratio.
  • High Accuracy Pressure Measurement, Temperature Measurements & Flow/return, inlet/outlet, hot/cold measurements.
  • CPA1 Kit includes GLD450 gas leak detector, KAL1 air / liquid probe temp probe, pressure hose, 2 x clamp on pipe probes, infra-red printer, rechargeable batteries and carry case.
  • Availability: Call us on 01782 567 099
pdf
(Size: 812.5 KB)
pdf
(Size: 888.7 KB)
More Information
Warranty6 years
Price MatchYes
Choice of FREE gift

Kane 457 CPA1 Combustion Analyser Kit

***Kane analysers are currently on an extended lead time. Please call us on 01782 567 099 for the current lead time***

The latest combustion analyser from Kane.

A flue gas analyser, domestic atmosphere analyser (with timed data-logging), differential thermometer and precision pressure meter all in a small, easy to use instrument.

Pro Kit comes complete with GLD450 gas leak detector, KAL1 air / liquid probe temp probe, pressure hose, 2 x clamp on pipe probes, infra-red printer, rechargeable batteries and carry case.

Accurately measures:

  • Carbon dioxide (CO2) in the range 0-20% volume, carbon monoxide (CO), flue and inlet temperature, differential pressure (±80mbar)
  • Oxygen (O2), CO/CO2 ratio, poison index, efficiency(gross, net and condensing)
  • Multi-fuel: Natural gas, light oil (28/35 sec), propane, butane, LPG, wood pellets
  • Long life sensors (expected life up to 5 years)
  • Detachable flue probe
  • Memory stores: 99 combustion tests, 20 pressure and tightness tests, 20 temperature and CO tests

Accurately measures:

  • Carbon dioxide (CO2) in the range 0-9999ppm and carbon monoxide (CO)
  • Timed room CO test
  • Ambient carbon dioxide (CO2) and carbon monoxide (CO) monitoring
  • Timed atmosphere logging (adjustable) with dual CO2 and CO printout (via optional infrared linked thermal printer)

Features:

  • Combustion Analysis - Ideal when installing & commissioning boilers, fires etc
  • Direct CO2 Measurement - Using Infra-red technology for better accuracy
  • Measure CO, CO2 & Ratio - For Benchmark logbook
  • Pressure & Temperature
  • High Accuracy Pressure Measurement - Perform timed let-by, stabilisation & tightness tests
  • Temperature Measurements (with optional probes)
  • Flow/return, inlet/outlet, hot/cold measurements
  • Air Quality
  • Room Ambient Air - Measure and record room CO2 and CO readings for up to 30 minutes
  • Ambient CO2 and CO - Monitor and record real time and maximum CO2 & CO
  • Timed Logging - Establish CO2 & CO concentration profiles over a specific period of time

What's Included?

  • GLD450 gas leak detector
  • KAL1 air / liquid probe temp probe
  • ASP2 appliance sampling probe kit
  • pressure hose
  • 2 x clamp on pipe probes
  • infra-red printer
  • rechargeable batteries
  • 12 charger
  • quick reference DVD
  • carry case

Specifications:

ParameterRangeResolutionAccuracy
Flue Temperature0-600°C0.1°C±2.0°C
±0.3% reading
Inlet Temperature0-50°C0.1°C±1.0°C
(Internal Sensor)±0.3% reading
Inlet Temperature0-600°C0.1°C±1.0°C
(External Sensor)±0.3% reading
Inlet Temperature0-600°C0.1°C±2.0°C
(External Sensor)±0.3% reading
Oxygen*20-21%0.10%±0.3%*1
Carbon monoxide0-20ppm1ppm±0.3%*1
21-2000ppm nom±3ppm
4,000ppm max for 15 mins±5% reading
Carbon dioxide0-20%0.10%±0.3% reading
Efficiency (Net or Gross)*20-99.9%0.10%±1.0% reading
Effeciency High (C)*20-119.9%0.10%±1.0% reading
Excess Air*20-250%0.10%±0.2% reading
CO/CO2 ratio *20-0.9990.0001±5% reading
Nominal range ±160mBar±0.2mBarMaximum±0.005 mBar
Maximum over range without damage to sensor is ±800mBar±1 mBar0.001 mBar±0.03 mBar
±160mBar<25 mBar±3% of reading

*1 Using dry gases at STP
*2 Calculated
Ambient Operating RangeTemperature - 0°C to 40°C
Humidity - 10% to 90% RH non-condensing
Atmospheric Pressure - 860 to 1060hPa
Battery Type / Life4AA cells
>8 hours using Alkaline AA cells
Chargers (optional)220v charger, for NiMH batteries only
12v in vehicle charger, for NiMH batteries only
DimensionsWeight - 0.8kg handset with protective cover
Handset - 200 x 45 x 90mm
Probe - 300mm long including handle. 6mm diameter x 240mm long stainless steel shaft with 3m neoprene hose. Type K thermocouple