TPI DC711-View Flue Gas Analyser

SKU: TPI/DC711-View Kit
MPN: DC711-View Kit
  • View-enabled DC711 analyser for use with or without TPI View App
  • Includes analyser, probe, charger and padded carry case
  • Pressure and tightness test feature
  • Differential temperature for flow and return or radiator balancing

£642.00 (ex VAT)

£770.40 (inc VAT)

Earn 642 points

In Stock - Express Delivery Available

Why buy from Test4Less?

  • View-enabled DC711 analyser for use with or without TPI View App
  • Includes analyser, probe, charger and padded carry case
  • Pressure and tightness test feature
  • Differential temperature for flow and return or radiator balancing
Free Shipping

Spend over £100 on any new goods order and receive automatic free shipping

Rewards

Points make purchases! For every £1 spent, earn back 1p that can be spent on any future new goods purchase

Our Price Promise

We offer a Price Match Promise! Find an equivalent tester for a cheaper price on a competitor site, and we’ll do our best to match it

Express Delivery & Calibration

Express Delivery is currently unavailable for customers wishing to add calibration to their New Goods order. For more information, visit our Delivery Information page. 

£642.00 (ex VAT)

£770.40 (inc VAT)

Earn 642 points

In Stock - Express Delivery Available

Customers also viewed

TPI DC711-View Flue Gas Analyser Kit

The TPI DC711-View Flue Gas Analyser Kit gives gas heating engineers and installers a View-enabled DC711 analyser in a ready-to-use kit format. The kit includes the DC711 analyser, probe and charger supplied in a padded carry case.

TPI positions the DC711-View for domestic or commercial use. It supports multiple fuel options and conforms to EN50379 Parts 1-3. In addition, it includes pressure and tightness testing, differential temperature measurement and TPI View App functionality.

Efficient Testing and Reporting

The DC711-View supports hold, save, print and send functions, so engineers can manage readings clearly during a job. It also includes a clear, easy to read screen and an easy to navigate menu system.

Use the analyser with or without the TPI View App. When used with the app, TPI View connects to compatible smart devices via Bluetooth and can show live results on a smartphone or tablet. It also allows users to save, email or print reports, while time, date and GPS stamped results help document when and where the job took place.

Built for Field Use

The DC711-View uses a backlit graphic LCD and a Li-ion 3.7V battery with more than 6 hours of battery life. It also uses a USB-C type charger input and operates from 14°F to +122°F, which is listed by TPI as -10°C to +50°C.

Key Features
  • View-enabled DC711 flue gas analyser kit
  • Designed for gas heating engineers and installers
  • Suitable for domestic or commercial use
  • Multiple fuel options
  • Hold, save, print and send functions
  • Clear, easy to read screen
  • Easy to navigate menu system
  • Pressure and tightness test feature
  • Differential temperature for flow and return or radiator balancing
  • Conforms to EN50379 Parts 1-3
Technical Specifications
SKU TPI/DC711-View Kit
Operating temperature range 14°F to +122°F (-10°C to +50°C)
Battery / battery life Li-ion 3.7V / > 6 hours
Charger input USB-C type
Fuels Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse
Pressure ranges mbar, psi, inH2O, mmH2O, kPa, hPa, inHg, mmHg, mH2O
Display Backlit Graphic LCD
Data storage 100 sets of readings, 30 sets for CO Build Up, multiple pages
Time and date 24 Hour Real Time Clock
Dimensions 7.28” (185mm) x 4.92” (125mm) x 2.56” (65mm)
Weight 1.83lbs (830g)
Conforms to EN50379 Parts 1-3
Flue temperature probe construction Pistol Grip with Stainless Steel Shaft
Flue temperature probe hose length 8.2’ (2500mm)
Flue temperature probe insertion length 7.9” (200mm)
K-Type thermocouple accuracy +/- 0.3% of fullscale, +/- 2°F (1°C)
Flue temperature probe maximum temperature 1472°F (800°C)
Oxygen Range: 0-25%; resolution: 0.1%; accuracy: +/- 0.3%
Carbon Monoxide (low) Range: 0-10,000 ppm; resolution: 1 ppm (<100ppm); accuracy: +/- 5 ppm (<100ppm), +/- 5% (>=100ppm)
Carbon Dioxide Range: 0-25%; resolution: 0.1%; calculated
CO/CO2 Ratio Range: 0-0.999; resolution: 0.001; calculated
Combustion Efficiency Range: 0-100%; resolution: 0.1%; calculated
Pressure measurement selectable ranges mbar, psi, inH2O, mmH2O, kPa, hPa, inHg, mmHg, mH2O
Pressure measurement range -150 mbar to +150 mbar; -15 kPa to +15 kPa; -60 inH2O to 60 inH2O
Pressure measurement resolution 0.001 mbar (0~9.999 mbar); 0.01 mbar (10.00~149.99 mbar)
Pressure measurement accuracy +/- 0.5 mbar FSD
Temperature measurement input type K-Type thermocouple
Temperature measurement range -58°F to 1832°F (-50°C to 1000°C)*
Temperature measurement resolution 1°F (1°C)
Temperature measurement accuracy +/- (0.3% of rdg + 2°F) or +/- (0.3% of rdg + 1°C)
What’s Included
  • View enabled DC711 Analyser
  • Probe
  • Charger
  • Padded Carry Case

TPI DC711-View Flue Gas Analyser Kit

The TPI DC711-View Flue Gas Analyser Kit gives gas heating engineers and installers a View-enabled DC711 analyser in a ready-to-use kit format. The kit includes the DC711 analyser, probe and charger supplied in a padded carry case.

TPI positions the DC711-View for domestic or commercial use. It supports multiple fuel options and conforms to EN50379 Parts 1-3. In addition, it includes pressure and tightness testing, differential temperature measurement and TPI View App functionality.

Efficient Testing and Reporting

The DC711-View supports hold, save, print and send functions, so engineers can manage readings clearly during a job. It also includes a clear, easy to read screen and an easy to navigate menu system.

Use the analyser with or without the TPI View App. When used with the app, TPI View connects to compatible smart devices via Bluetooth and can show live results on a smartphone or tablet. It also allows users to save, email or print reports, while time, date and GPS stamped results help document when and where the job took place.

Built for Field Use

The DC711-View uses a backlit graphic LCD and a Li-ion 3.7V battery with more than 6 hours of battery life. It also uses a USB-C type charger input and operates from 14°F to +122°F, which is listed by TPI as -10°C to +50°C.

Key Features
  • View-enabled DC711 flue gas analyser kit
  • Designed for gas heating engineers and installers
  • Suitable for domestic or commercial use
  • Multiple fuel options
  • Hold, save, print and send functions
  • Clear, easy to read screen
  • Easy to navigate menu system
  • Pressure and tightness test feature
  • Differential temperature for flow and return or radiator balancing
  • Conforms to EN50379 Parts 1-3
Technical Specifications
SKU TPI/DC711-View Kit
Operating temperature range 14°F to +122°F (-10°C to +50°C)
Battery / battery life Li-ion 3.7V / > 6 hours
Charger input USB-C type
Fuels Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse
Pressure ranges mbar, psi, inH2O, mmH2O, kPa, hPa, inHg, mmHg, mH2O
Display Backlit Graphic LCD
Data storage 100 sets of readings, 30 sets for CO Build Up, multiple pages
Time and date 24 Hour Real Time Clock
Dimensions 7.28” (185mm) x 4.92” (125mm) x 2.56” (65mm)
Weight 1.83lbs (830g)
Conforms to EN50379 Parts 1-3
Flue temperature probe construction Pistol Grip with Stainless Steel Shaft
Flue temperature probe hose length 8.2’ (2500mm)
Flue temperature probe insertion length 7.9” (200mm)
K-Type thermocouple accuracy +/- 0.3% of fullscale, +/- 2°F (1°C)
Flue temperature probe maximum temperature 1472°F (800°C)
Oxygen Range: 0-25%; resolution: 0.1%; accuracy: +/- 0.3%
Carbon Monoxide (low) Range: 0-10,000 ppm; resolution: 1 ppm (<100ppm); accuracy: +/- 5 ppm (<100ppm), +/- 5% (>=100ppm)
Carbon Dioxide Range: 0-25%; resolution: 0.1%; calculated
CO/CO2 Ratio Range: 0-0.999; resolution: 0.001; calculated
Combustion Efficiency Range: 0-100%; resolution: 0.1%; calculated
Pressure measurement selectable ranges mbar, psi, inH2O, mmH2O, kPa, hPa, inHg, mmHg, mH2O
Pressure measurement range -150 mbar to +150 mbar; -15 kPa to +15 kPa; -60 inH2O to 60 inH2O
Pressure measurement resolution 0.001 mbar (0~9.999 mbar); 0.01 mbar (10.00~149.99 mbar)
Pressure measurement accuracy +/- 0.5 mbar FSD
Temperature measurement input type K-Type thermocouple
Temperature measurement range -58°F to 1832°F (-50°C to 1000°C)*
Temperature measurement resolution 1°F (1°C)
Temperature measurement accuracy +/- (0.3% of rdg + 2°F) or +/- (0.3% of rdg + 1°C)
What’s Included
  • View enabled DC711 Analyser
  • Probe
  • Charger
  • Padded Carry Case

Ask a question