Megger DCI3 Cable & Phase Identification System

  • 50 V DC pulse cable identification
  • Phase ID up to 30 km operation
  • IP54 field-ready TX and receiver
  • LCI TX supports 100 to 440 V AC

This product is made to order. Please contact us on 01782 567099 to place an order.

Free Shipping

Spend over £100 on any new goods order and receive automatic free shipping

Rewards

Points make purchases! For every £1 spent, earn back 1p that can be spent on any future new goods purchase

Our Price Promise

We offer a Price Match Promise! Find an equivalent tester for a cheaper price on a competitor site, and we’ll do our best to match it

Express Delivery & Calibration

Express Delivery is currently unavailable for customers wishing to add calibration to their New Goods order. For more information, visit our Delivery Information page. 

Earn 0 points

Contact Us For Delivery Estimate
  • 50 V DC pulse cable identification
  • Phase ID up to 30 km operation
  • IP54 field-ready TX and receiver
  • LCI TX supports 100 to 440 V AC

This product is made to order. Please contact us on 01782 567099 to place an order.

Free Shipping

Spend over £100 on any new goods order and receive automatic free shipping

Rewards

Points make purchases! For every £1 spent, earn back 1p that can be spent on any future new goods purchase

Our Price Promise

We offer a Price Match Promise! Find an equivalent tester for a cheaper price on a competitor site, and we’ll do our best to match it

Express Delivery & Calibration

Express Delivery is currently unavailable for customers wishing to add calibration to their New Goods order. For more information, visit our Delivery Information page. 

Earn 0 points

Contact Us For Delivery Estimate
Product Question
Name
Name
Plain text only. HTML is not allowed.
 

Megger DCI3 Cable and Phase Identification System

The Megger DCI3 Cable and Phase Identification System helps teams identify cables and phases before cutting, jointing, splicing, or repair work. It supports safe checks on de-energised cables and live low-voltage cables when used with the optional LCI transmitter. As a result, site teams can reduce the risk of wrong cable work, equipment damage, and service interruption.

Operators can use the system on utility networks, rail sites, renewable energy plants, cable contractor projects, and industrial facilities. It is designed for clear cable selection within bundles, even when cable routes are long. In cable identification mode, the transmitter uses a 50 V DC pulse with up to 25 A pulse current.

 

Safer Grounded Working

Megger DCI3 lets teams identify phases while cable ends stay grounded. This improves field safety and helps protect personnel during network work. In addition, passive clamp technology detects phases securely without removing the ground connection.

The system identifies cable lengths up to 30 km, so teams can use it on larger networks and long route checks. Optional 150 mm flexible clamps help users work around larger cable sections and tight cabinet spaces. This gives engineers more choice when access is limited or conductors are hard to reach.

 

Field Use and Live Cable Support

Fast setup helps crews complete checks with less delay. The touchscreen and rotary encoder give simple control in the field, while the compact design supports regular transport between sites. The Megger DCI3 Cable and Phase Identification System also uses a rechargeable lithium-ion battery for practical daily use.

With the optional LCI TX, the system can identify phase to phase on energised cables from 100 to 440 V AC. It runs at 50/60 Hz and delivers an 80 A pulse current for live low-voltage work. Therefore, the Megger DCI3 Cable and Phase Identification System can support both planned outage work and checks where service continuity matters.

 

Key Features

  • Cable and phase identification in one field-ready system
  • Supports de-energised and energised low-voltage cable work
  • Phase identification can be completed while grounded
  • Reliable cable selection before cutting or splicing tasks
  • Helps reduce accidental outages and cable damage
  • Suitable for utilities, railways, contractors, and industry
  • Passive clamp technology supports safe phase checks
  • Optional active flexible clamps support tight access areas
  • Touchscreen and rotary encoder give simple operation
  • Compact IP54 design supports demanding field use
  • Supports cable lengths up to 30 km
  • Useful for network extensions, repairs, and maintenance

 

Technical Specifications

Product name Megger DCI3 Cable and Phase Identification System
Transmitter function Cable and phase identification on de-energised cables
Cable identification pulse voltage 50 V DC
Cable identification pulse current Maximum 25 A
Cable identification pulse frequency 36 pulses/min in CI-1 and DF modes, 12 per phase/min in CI-3 mode
Cable identification pulse width 144 ms
Cable identification operational distance Maximum 30 km
Phase identification output bandwidth 1 kHz to 8 kHz
Phase identification frequency selection Automatic
Phase identification distance Maximum 30 km with CPIC50 clamps
DCI3 battery Rechargeable lithium-ion, 7.2 V / 4.4 Ah
DCI3 battery life CI mode up to 6 hours, PI mode over 100 measurements
Display 4.3 inch TFT WQVGA, 480 x 272, 425 cd/m² LED touch
DCI3 measurement category 300 V CAT IV, DIN EN 61010-1
DCI3 protection class IP54, III DIN EN 615029, DIN EN 61140
DCI3 dimensions 274 x 96 x 143 mm
DCI3 weight Less than 2 kg
DCI3 operating conditions -10°C to +55°C, RH 93% at 30°C
DCI3 storage conditions -25°C to +65°C, RH 95% at 40°C
RX3 sensors AZF 250-CI, TFS CI
RX3 optional sensors AZF 150-CI, PAS CI
RX3 amplification 8 steps
RX3 dynamic range -3 dB to 24 dB
RX3 battery 2 x 1.5 V AA
RX3 battery life Over 50 hours
RX3 measurement category 300 V CAT IV, IEC 61010-1
RX3 dimensions 150 x 65 x 35 mm
RX3 weight 0.4 kg
LCI TX operating voltage 100 to 440 V AC, 50/60 Hz
LCI TX pulse current 80 A
LCI TX pulse frequency 30 pulses/min
LCI TX pulse width 1.5 ms
LCI TX dimensions 151 x 101 x 60 mm
LCI TX weight 0.5 kg
Manufacturer part code Not provided
Warranty Not provided

 

Comparison Table

Item DCI3 transmitter RX3 receiver LCI TX transmitter
Main use Cable and phase identification on de-energised cables Signal receiving with compatible sensors Phase to phase identification on energised cables
Operating voltage 50 V DC pulse voltage Not provided 100 to 440 V AC, 50/60 Hz
Pulse current Maximum 25 A Not provided 80 A
Pulse frequency 36 pulses/min or 12 per phase/min Not provided 30 pulses/min
Pulse width 144 ms Not provided 1.5 ms
Battery Li-ion rechargeable, 7.2 V / 4.4 Ah 2 x 1.5 V AA Not provided
Protection class IP54 IP54 IP54
Dimensions 274 x 96 x 143 mm 150 x 65 x 35 mm 151 x 101 x 60 mm
Weight Less than 2 kg 0.4 kg 0.5 kg
Operating conditions -10°C to +55°C, RH 93% at 30°C -10°C to +55°C, RH 93% at 30°C -10°C to +60°C, RH 93% at 30°C

 

Document Downloads

pdf
pdf

What’s Included

  • Megger DCI3 transmitter for cable and phase identification
  • RX3 receiver
  • Second battery
pdf
pdf

Megger DCI3 Cable and Phase Identification System

The Megger DCI3 Cable and Phase Identification System helps teams identify cables and phases before cutting, jointing, splicing, or repair work. It supports safe checks on de-energised cables and live low-voltage cables when used with the optional LCI transmitter. As a result, site teams can reduce the risk of wrong cable work, equipment damage, and service interruption.

Operators can use the system on utility networks, rail sites, renewable energy plants, cable contractor projects, and industrial facilities. It is designed for clear cable selection within bundles, even when cable routes are long. In cable identification mode, the transmitter uses a 50 V DC pulse with up to 25 A pulse current.

 

Safer Grounded Working

A key benefit of the Megger DCI3 Cable and Phase Identification System is that phase identification can be carried out while cable ends remain grounded. This supports safer field practice and helps protect personnel during network work. In addition, passive clamp technology provides secure phase detection without the need to remove grounding during the process.

The system can identify cable lengths up to 30 km, making it useful for larger networks and long route checks. For larger cable sections or tight cabinet spaces, optional flexible 150 mm clamps are available. This gives teams more choice when access is limited or when conductors are difficult to reach.

 

Field Use and Live Cable Support

Fast setup helps crews complete checks with less delay. The touchscreen and rotary encoder give simple control in the field, while the compact design supports regular transport between sites. The Megger DCI3 Cable and Phase Identification System also uses a rechargeable lithium-ion battery for practical daily use.

With the optional LCI TX, the system can identify phase to phase on energised cables from 100 to 440 V AC. It runs at 50/60 Hz and delivers an 80 A pulse current for live low-voltage work. Therefore, the Megger DCI3 Cable and Phase Identification System can support both planned outage work and checks where service continuity matters.

 

Key Features

  • Cable and phase identification in one field-ready system
  • Supports de-energised and energised low-voltage cable work
  • Phase identification can be completed while grounded
  • Reliable cable selection before cutting or splicing tasks
  • Helps reduce accidental outages and cable damage
  • Suitable for utilities, railways, contractors, and industry
  • Passive clamp technology supports safe phase checks
  • Optional active flexible clamps support tight access areas
  • Touchscreen and rotary encoder give simple operation
  • System options can be retrofitted independently
  • Compact IP54 design supports demanding field use
  • Second battery is included for longer working time
  • Supports cable lengths up to 30 km
  • Useful for network extensions, repairs, and maintenance

 

Technical Specifications

Product name Megger DCI3 Cable and Phase Identification System
Transmitter function Cable and phase identification on de-energised cables
Cable identification pulse voltage 50 V DC
Cable identification pulse current Maximum 25 A
Cable identification pulse frequency 36 pulses/min in CI-1 and DF modes, 12 per phase/min in CI-3 mode
Cable identification pulse width 144 ms
Cable identification operational distance Maximum 30 km
Phase identification output bandwidth 1 kHz to 8 kHz
Phase identification frequency selection Automatic
Phase identification distance Maximum 30 km with CPIC50 clamps
DCI3 battery Rechargeable lithium-ion, 7.2 V / 4.4 Ah
DCI3 battery life CI mode up to 6 hours, PI mode over 100 measurements
Display 4.3 inch TFT WQVGA, 480 x 272, 425 cd/m² LED touch
DCI3 measurement category 300 V CAT IV, DIN EN 61010-1
DCI3 protection class IP54, III DIN EN 615029, DIN EN 61140
DCI3 dimensions 274 x 96 x 143 mm
DCI3 weight Less than 2 kg
DCI3 operating conditions -10°C to +55°C, RH 93% at 30°C
DCI3 storage conditions -25°C to +65°C, RH 95% at 40°C
RX3 sensors AZF 250-CI, TFS CI
RX3 optional sensors AZF 150-CI, PAS CI
RX3 amplification 8 steps
RX3 dynamic range -3 dB to 24 dB
RX3 battery 2 x 1.5 V AA
RX3 battery life Over 50 hours
RX3 measurement category 300 V CAT IV, IEC 61010-1
RX3 dimensions 150 x 65 x 35 mm
RX3 weight 0.4 kg
LCI TX operating voltage 100 to 440 V AC, 50/60 Hz
LCI TX pulse current 80 A
LCI TX pulse frequency 30 pulses/min
LCI TX pulse width 1.5 ms
LCI TX dimensions 151 x 101 x 60 mm
LCI TX weight 0.5 kg
Manufacturer part code Not provided
Warranty Not provided

 

 

DCI3 Configuration Options

The DCI3 is a configurable solution. Select one mandatory system option, then pair it with the required system licence. Optional accessories can also be added to suit cable identification and phase identification work on energised and de-energised systems.

 

System Options

Option Description Order No.
CI – Cable Identification Includes VK 184 generator connection cable, RX3 receiver, AZF 250-CI flexible clamp, and TFS CI twisted field sensor 1016650
LCI – Cable Identification Includes LCI TX-440 generator and set of 3 connection cables with crocodile clamps 1016654
PI-A – Phase Identification Includes VK 185 generator connection cable and set of 3 clamps in transport case 1016651
PI-AB – Phase Identification Includes VK 185 generator connection cable and two clamp sets 1016652
PI-FA – Phase Identification Includes VK 185 generator connection cable and set of 3 flexible clamps 1017279
PI-FAB – Phase Identification Includes VK 185 generator connection cable and two flexible clamp sets 1017280

 

System Licences

Licence Type Description Order No.
CI Licence Enables cable identification functionality for de-energised cables 1380
PI Licence Enables phase identification functionality 1381
CI + PI Licence Enables both cable and phase identification within a single system 1383

Document Downloads

pdf
pdf

What’s Included

  • Megger DCI3 transmitter for cable and phase identification
  • RX3 receiver
  • Second battery

QUESTIONS

Related Products