Kane 458s Flue Gas Analyser with CPA KIT2
The Kane 458s Flue Gas Analyser with CPA KIT2 combines the KANE458s domestic and commercial flue gas analyser with the official Kane CPA KIT2 accessory bundle. This configured product includes the base analyser, CP2 combustion probe, pressure hose, protective case, carry bag and the CPA KIT2 accessories.
The KANE458s measures flue gas O2, CO2 with NDIR technology and CO to 10,000ppm with H2 compensation and overrange protection. It also measures differential temperature and uses 1 psi differential pressure sensors. In addition, it includes a water stop particle filter, large graphic display, KANE LOCK and TÜV approval to EN50379 and EN50543.
Expanded Wireless Appliance Testing Setup
The included CPA KIT2 builds on the PRO KIT2. It adds a KANE-GLD leak detector, a KAL1 general purpose temperature probe, 2 WPCP wireless clamp-on pipe temperature probes and ASP3 cooker, grill and gas fire appliance testing probes.
As a result, this configured product gives engineers the KANE458s analyser with added accessories for leak detection, general temperature measurement, wireless pipe temperature measurement and appliance testing. Therefore, it provides the base KANE458s setup plus the official CPA KIT2 accessories in one product.
Built for Site Work
The KANE458s is supplied with a pressure hose, CP2 combustion probe, 3 rechargeable batteries, USB1 charger, MSC00237 protective case and 14102/2 carry bag. Meanwhile, the CPA KIT2 adds the accessories listed by Kane for PRO KIT2 plus ASP3 cooker, grill and gas fire appliance testing probes.
Key Features
- Configured product with KANE458s base analyser and CPA KIT2
- Measures flue gas O2, CO2 with NDIR technology and CO to 10,000ppm
- CO measurement includes H2 compensation and overrange protection
- 1 psi differential pressure sensors
- Differential temperature measurement
- Water stop particle filter
- Large graphic display
- KANE LOCK included on the analyser
- CPA KIT2 includes PRO KIT2 accessories plus ASP3 appliance testing probes
- TÜV approved to EN50379 and EN50543
Technical Specifications
| Configured product | KANE458s with CPA KIT2 |
|---|---|
| Base analyser | KANE458s |
| Kit included | CPA KIT2 |
| Standard gas measurements | O2, CO2 with NDIR technology and CO to 10,000ppm |
| CO measurement | To 10,000ppm with H2 compensation and overrange protection |
| Differential pressure | 1 psi differential pressure sensors |
| Differential temperature | Included |
| Particle protection | Water stop particle filter |
| Display | Large graphic display |
| Security feature | KANE LOCK |
| Approvals | TÜV approved to EN50379 and EN50543 |
| CPA KIT2 leak detector | KANE-GLD leak detector |
| CPA KIT2 temperature probe | KAL1 general purpose temperature probe |
| CPA KIT2 wireless pipe probes | 2 WPCP wireless clamp-on pipe temperature probes |
| CPA KIT2 appliance probes | ASP3 cooker, grill and gas fire appliance testing probes |
Sensor Options
| Website option | Official sensor option | Range | Configuration note |
|---|---|---|---|
| No extra sensor | Base KANE458s configuration | Standard analyser measurements | Uses the standard KANE458s setup listed in the October 2025 price list |
| NO sensor 0-600ppm | NO sensor | 0-600ppm | Optional KANE458s sensor listed in the October 2025 price list |
| Ambient CO2 sensor 0-9999ppm | Ambient CO2 sensor | 0-9999ppm | Also replaces the flue CO2 sensor with O2 sensor FOC |
What’s Included
- KANE458s analyser
- Pressure hose
- CP2 combustion probe
- 3 rechargeable batteries
- USB1 charger
- MSC00237 protective case
- 14102/2 carry bag
- KANE-GLD leak detector
- KAL1 general purpose temperature probe
- 2 WPCP wireless clamp-on pipe temperature probes
- ASP3 cooker, grill and gas fire appliance testing probes