CIE LV50 50v AC Non-contact Voltage Tester (ATEX Rated)

SKU: CIE/LV50
  • Designed for hazardous-area field engineers
  • Detects AC voltage without direct contact
  • 50 to 1000V AC operating voltage range
  • ATEX and IECEx approved for hazardous areas

£50.00 (ex VAT)

£60.00 (inc VAT)

Earn 50 points

Usually ships In 1 to 2 weeks

Why buy from Test4Less?

  • Designed for hazardous-area field engineers
  • Detects AC voltage without direct contact
  • 50 to 1000V AC operating voltage range
  • ATEX and IECEx approved for hazardous areas
Free Shipping

Spend over £100 on any new goods order and receive automatic free shipping

Rewards

Points make purchases! For every £1 spent, earn back 1p that can be spent on any future new goods purchase

Our Price Promise

We offer a Price Match Promise! Find an equivalent tester for a cheaper price on a competitor site, and we’ll do our best to match it

Express Delivery & Calibration

Express Delivery is currently unavailable for customers wishing to add calibration to their New Goods order. For more information, visit our Delivery Information page. 

£50.00 (ex VAT)

£60.00 (inc VAT)

Earn 50 points

Usually ships In 1 to 2 weeks

Customers also viewed

CIE LV50 50v AC Non-contact Voltage Tester

CIE LV50 50v AC Non-contact Voltage Tester detects AC voltages from 50V to 1000V without direct contact. Engineers can use it to identify potentially live metallic surfaces, pipework and cables while avoiding contact with the conductor. Its 50V detection level also helps users find unexpected or spurious live voltages in materials, devices and work areas.

Engineers can use the tester in hazardous and potentially explosive atmospheres thanks to its ATEX and IECEx intrinsic safety approvals. The fully insulated construction supports safe handling, while the safety handguard helps users avoid unintended contact with live conductors. The tester responds immediately when it detects voltage under the stated sensitivity conditions.

CIE LV50 50v AC Non-contact Voltage Tester suits engineers working across utilities, infrastructure, gas and petrochemical applications. Organisations including Shell, Network Rail and Cadent approve the LV50 for use, while National Grid specifies it for use by engineers. The tester combines non-contact voltage detection with CAT IV 1000V AC approval, IP64 ingress protection and a compact 0.04kg design.

 

Key Benefits
  • Non-contact operation allows AC voltage checks without direct contact with the conductor.
  • Detection from 50V AC helps identify lower-voltage, unexpected and spurious live voltages.
  • ATEX and IECEx approval supports work in hazardous and potentially explosive atmospheres.
  • Immediate response gives engineers a fast indication when voltage is detected.
  • The safety handguard helps reduce accidental contact with live conductors during use.
  • Fully insulated construction supports safer handling during electrical checks.
  • CAT IV 1000V AC approval supports use in demanding electrical environments.
  • IP64 ingress protection supports use in field and industrial environments.
  • Two standard AAA alkaline batteries provide a simple replaceable power source.

 

Common Applications

CIE LV50 50v AC Non-contact Voltage Tester is suitable for a range of testing, maintenance and inspection tasks, including:

  • Checking metallic surfaces for potentially live AC voltage.
  • Checking pipework for unexpected or spurious live voltage.
  • Non-contact voltage checking on cables.
  • Low-voltage and industrial AC voltage detection from 50V.
  • Electrical checks in hazardous and potentially explosive atmospheres.
  • Field engineering work for utility and infrastructure providers.
  • Voltage checking in gas industry applications.
  • Voltage checking in petrochemical applications.

 

Why Choose This Model?

CIE LV50 50v AC Non-contact Voltage Tester combines a 50 to 1000V AC detection range with non-contact operation, intrinsic safety and ATEX and IECEx approval. Its CAT IV 1000V AC rating, IP64 protection, safety handguard and fully insulated construction make it well suited to hazardous-area field work.

pdf
CIE LV50 50v AC Non-contact Voltage Tester

CIE LV50 50v AC Non-contact Voltage Tester is a non-contact voltage indicator designed to detect AC voltages from 50V to 1000V. It enables engineers to identify potentially live metallic surfaces, pipework and cables without direct contact with the conductor. Detection down to 50V AC also helps identify unexpected or spurious live voltages in materials, devices and work areas.

Designed for hazardous and potentially explosive atmospheres, the tester is ATEX and IECEx approved as intrinsically safe. Its fully insulated construction supports safe handling, while the safety handguard helps prevent unintended contact with live conductors. An immediate response provides fast indication when voltage is detected under the stated sensitivity conditions.

CIE LV50 50v AC Non-contact Voltage Tester is suited to engineers working across utilities, infrastructure, gas and petrochemical applications. The LV50 is approved for use by organisations including Shell, Network Rail and Cadent, and is specified for use by engineers within organisations including National Grid. It combines non-contact voltage detection with CAT IV 1000V AC approval, IP64 ingress protection and a compact 0.04kg design.

 

Key Benefits
  • Non-contact operation allows AC voltage checks without direct contact with the conductor.
  • Detection from 50V AC helps identify lower-voltage, unexpected and spurious live voltages.
  • ATEX and IECEx approval supports work in hazardous and potentially explosive atmospheres.
  • Immediate response gives engineers a fast indication when voltage is detected.
  • The safety handguard helps reduce accidental contact with live conductors during use.
  • Fully insulated construction supports safer handling during electrical checks.
  • CAT IV 1000V AC approval supports use in demanding electrical environments.
  • IP64 ingress protection supports use in field and industrial environments.
  • Two standard AAA alkaline batteries provide a simple replaceable power source.

 

Common Applications

CIE LV50 50v AC Non-contact Voltage Tester is suitable for a range of testing, maintenance and inspection tasks, including:

  • Checking metallic surfaces for potentially live AC voltage.
  • Checking pipework for unexpected or spurious live voltage.
  • Non-contact voltage checking on cables.
  • Low-voltage and industrial AC voltage detection from 50V.
  • Electrical checks in hazardous and potentially explosive atmospheres.
  • Field engineering work for utility and infrastructure providers.
  • Voltage checking in gas industry applications.
  • Voltage checking in petrochemical applications.

 

Why Choose This Model?

CIE LV50 50v AC Non-contact Voltage Tester combines a 50 to 1000V AC detection range with non-contact operation, intrinsic safety and ATEX and IECEx approval. Its CAT IV 1000V AC rating, IP64 protection, safety handguard and fully insulated construction make it well suited to hazardous-area field work.

General Specifications
Specification Details
Product type Non-contact AC voltage indicator
Detection method Non-contact voltage detection
Intrinsically safe Yes
Hazardous-area approvals ATEX and IECEx approved
Safety approval IECEx 61010-1, CAT IV 1000V AC
Additional approvals UKCA and CE approved
Ingress protection IP64
Power supply 2 x standard AAA alkaline batteries
Construction Fully insulated
Safety handguard Yes

 

Measurement and Accuracy Specifications
Specification Details
Measurement function AC voltage detection
Voltage range 50 to 1000V AC
Sensitivity Indicator illuminates at a distance of 4mm from a 2.5mm conductor carrying 50V
Response time Immediate
Overvoltage category CAT IV 1000V AC

 

Mechanical and General Information
Specification Details
Operating temperature -20 to +50°C
Relative humidity 80% at 30°C; 50% at 40°C
Dimensions 145(L) x 18(Ø)mm
Weight 0.04kg
Battery type Standard AAA alkaline batteries
Battery quantity 2

 

Specification Notes
  • The 50V sensitivity figure applies when the indicator is 4mm from a 2.5mm conductor carrying 50V.
  • The tester is intrinsically safe and carries both ATEX and IECEx approval for hazardous-area use.
  • The electrical safety category is CAT IV 1000V AC.

What’s Included
  • CIE LV50 50v AC Non-contact Voltage Tester
  • 2 x standard AAA alkaline batteries

Ask a question