Chauvin Arnoux CA1864 Infrared Thermometer

  • Ideal for non-contact surface inspections
  • Wide temperature range from -50 to 1000°C
  • 30:1 targeting ratio for distant readings
  • Adjustable emissivity for varied surfaces

£242.50 (ex VAT)

£291.00 (inc VAT)

Earn 242 points

Usually ships In 1 to 2 weeks

Why buy from Test4Less?

  • Ideal for non-contact surface inspections
  • Wide temperature range from -50 to 1000°C
  • 30:1 targeting ratio for distant readings
  • Adjustable emissivity for varied surfaces
Free Shipping

Spend over £100 on any new goods order and receive automatic free shipping

Rewards

Points make purchases! For every £1 spent, earn back 1p that can be spent on any future new goods purchase

Our Price Promise

We offer a Price Match Promise! Find an equivalent tester for a cheaper price on a competitor site, and we’ll do our best to match it

Express Delivery & Calibration

Express Delivery is currently unavailable for customers wishing to add calibration to their New Goods order. For more information, visit our Delivery Information page. 

£242.50 (ex VAT)

£291.00 (inc VAT)

Earn 242 points

Usually ships In 1 to 2 weeks

Customers also viewed

Chauvin Arnoux CA1864 Infrared Thermometer

The Chauvin Arnoux CA1864 Infrared Thermometer provides a practical way to measure surface temperatures without direct contact. With a wide temperature range of -50°C to 1000°C, it is suitable for a range of temperature checks and inspection tasks. Its 30:1 distance-to-spot ratio allows readings to be taken from a distance while targeting a defined measurement area. A built-in Class II laser pointer helps users aim at the required measurement point.

Adjustable emissivity gives users greater control when measuring different types of surfaces. The Chauvin Arnoux CA1864 Infrared Thermometer allows emissivity settings from 0.1 to 1, helping maintain measurement accuracy on surfaces that need different settings. Its scanning function helps users locate hot spots quickly, while configurable high and low temperature alarms highlight readings that exceed preset limits. Maximum, minimum, average and difference functions also help users assess changes in temperature during inspections.

For day-to-day use, the pistol-shaped body provides a comfortable handheld design with simple trigger operation. Holding the trigger enables continuous measurements, while the data hold function keeps a reading on the display for review. A 20,000-count backlit screen makes measured values easier to see, and users can select readings in Celsius or Fahrenheit. Combining a wide measurement range with flexible settings and clear display functions, the Chauvin Arnoux CA1864 Infrared Thermometer offers a convenient solution for surface temperature measurement.

 

Key Benefits
  • Take surface temperature readings without making direct contact with the measured area.
  • Measure from a distance using the 30:1 distance-to-spot ratio and built-in laser pointer.
  • Adjust emissivity to help maintain accurate readings across different surface types.
  • Scan target areas to identify hot spots during temperature inspections.
  • Set high and low temperature alarms to highlight readings outside chosen limits.
  • Review maximum, minimum, average and difference values to assess temperature changes.
  • Keep measured values visible with the data hold function for easier review.
  • Read results clearly using the 20,000-count backlit display.
  • Carry out continuous measurements by holding the trigger, without restarting each reading.

 

Common Applications

The Chauvin Arnoux CA1864 Infrared Thermometer is suitable for a range of testing, maintenance and inspection tasks, including:

  • Routine non-contact surface temperature checks.
  • Surface temperature inspections during maintenance work.
  • Scanning measurement areas to locate hot spots.
  • Checking surfaces that require adjustable emissivity settings.
  • Monitoring temperatures against preset high alarm thresholds.
  • Checking temperatures against preset low alarm thresholds.
  • Comparing maximum and minimum temperature readings.
  • Reviewing average temperature and differences between measured values.
  • Taking targeted surface temperature readings from a distance.

 

Why Choose This Model?

The Chauvin Arnoux CA1864 extends the maximum measurement temperature to 1000°C, compared with 550°C for the CA879. Its adjustable emissivity, 30:1 distance-to-spot ratio and additional measurement functions make it a strong choice for users who need greater control over surface temperature checks.

Chauvin Arnoux CA1864 Infrared Thermometer

The Chauvin Arnoux CA1864 Infrared Thermometer provides a practical way to measure surface temperatures without direct contact. With a wide temperature range of -50°C to 1000°C, it is suitable for a range of temperature checks and inspection tasks. Its 30:1 distance-to-spot ratio allows readings to be taken from a distance while targeting a defined measurement area. A built-in Class II laser pointer helps users aim at the required measurement point.

Adjustable emissivity gives users greater control when measuring different types of surfaces. The Chauvin Arnoux CA1864 Infrared Thermometer allows emissivity settings from 0.1 to 1, helping maintain measurement accuracy on surfaces that need different settings. Its scanning function helps users locate hot spots quickly, while configurable high and low temperature alarms highlight readings that exceed preset limits. Maximum, minimum, average and difference functions also help users assess changes in temperature during inspections.

For day-to-day use, the pistol-shaped body provides a comfortable handheld design with simple trigger operation. Holding the trigger enables continuous measurements, while the data hold function keeps a reading on the display for review. A 20,000-count backlit screen makes measured values easier to see, and users can select readings in Celsius or Fahrenheit. Combining a wide measurement range with flexible settings and clear display functions, the Chauvin Arnoux CA1864 Infrared Thermometer offers a convenient solution for surface temperature measurement.

 

Key Benefits
  • Take surface temperature readings without making direct contact with the measured area.
  • Measure from a distance using the 30:1 distance-to-spot ratio and built-in laser pointer.
  • Adjust emissivity to help maintain accurate readings across different surface types.
  • Scan target areas to identify hot spots during temperature inspections.
  • Set high and low temperature alarms to highlight readings outside chosen limits.
  • Review maximum, minimum, average and difference values to assess temperature changes.
  • Keep measured values visible with the data hold function for easier review.
  • Read results clearly using the 20,000-count backlit display.
  • Carry out continuous measurements by holding the trigger, without restarting each reading.

 

Common Applications

The Chauvin Arnoux CA1864 Infrared Thermometer is suitable for a range of testing, maintenance and inspection tasks, including:

  • Routine non-contact surface temperature checks.
  • Surface temperature inspections during maintenance work.
  • Scanning measurement areas to locate hot spots.
  • Checking surfaces that require adjustable emissivity settings.
  • Monitoring temperatures against preset high alarm thresholds.
  • Checking temperatures against preset low alarm thresholds.
  • Comparing maximum and minimum temperature readings.
  • Reviewing average temperature and differences between measured values.
  • Taking targeted surface temperature readings from a distance.

 

Why Choose This Model?

The Chauvin Arnoux CA1864 extends the maximum measurement temperature to 1000°C, compared with 550°C for the CA879. Its adjustable emissivity, 30:1 distance-to-spot ratio and additional measurement functions make it a strong choice for users who need greater control over surface temperature checks.

Product Comparison
Feature Chauvin Arnoux CA1864 Chauvin Arnoux CA879
Product type Infrared thermometer Infrared thermometer
Maximum measurement temperature 1000°C 550°C
Adjustable emissivity Yes, 0.1 to 1 No

 

General Specifications
Specification Details
Manufacturer Chauvin Arnoux
Model CA1864
Product type Non-contact infrared thermometer
Display 20,000-count display
Backlight Yes
Data hold function Yes
Laser sight Built-in, Class II
Alarm functions Configurable high and low temperature thresholds
Measurement units °C and °F
Power supply 9V battery

 

Measurement and Accuracy Specifications
Specification Details
Measurement method Non-contact infrared
Temperature range -50°C to +1000°C
Resolution 0.1°C
Distance-to-spot ratio 30:1
Emissivity adjustment 0.1 to 1
Accuracy: -50°C to -20°C ±5°C
Accuracy: 20°C to +200°C ±1.5% of reading ±2°C
Accuracy: +200°C to +538°C ±2.0% of reading ±2°C
Accuracy: +538°C to +1000°C ±3.5% of reading ±5°C
Reading functions MAX, MIN, AVG, DIFF and HOLD
Scanning function Yes, for detecting hot spots
Continuous measurement By holding the trigger

 

Mechanical and General Information
Specification Details
Dimensions 230 × 100 × 56 mm
Weight 290 g
Instrument design Handheld, pistol-shaped body
Measurement control Trigger-operated
Battery type 9V battery
Carrying method Carrying case included

 

Specification Notes
  • Temperature accuracy varies across the measurement range, with separate figures for -50°C to -20°C, 20°C to 200°C, 200°C to 538°C and 538°C to 1000°C.
  • The 30:1 distance-to-spot ratio gives a nominal measurement spot of 1 inch at a distance of 30 inches.
  • Emissivity can be adjusted from 0.1 to 1 to suit the surface being measured.
What’s Included
  • Chauvin Arnoux CA1864 Infrared Thermometer
  • Carrying case
  • Operating manual
  • 9V battery

Ask a question

Ask a question | Product pages