Fluke ii1050 Acoustic Imager

  • Ideal for plant reliability and maintenance teams
  • Detects air, gas and vacuum leaks up to 150 m
  • Locates electrical partial discharge with PDQ
  • Identifies bearing faults and friction with MecQ

£16,328.00 (ex VAT)

£19,593.60 (inc VAT)

Earn 16328 points

Contact us for delivery date

Why buy from Test4Less?

  • Ideal for plant reliability and maintenance teams
  • Detects air, gas and vacuum leaks up to 150 m
  • Locates electrical partial discharge with PDQ
  • Identifies bearing faults and friction with MecQ
Free Shipping

Spend over £100 on any new goods order and receive automatic free shipping

Rewards

Points make purchases! For every £1 spent, earn back 1p that can be spent on any future new goods purchase

Our Price Promise

We offer a Price Match Promise! Find an equivalent tester for a cheaper price on a competitor site, and we’ll do our best to match it

Express Delivery & Calibration

Express Delivery is currently unavailable for customers wishing to add calibration to their New Goods order. For more information, visit our Delivery Information page. 

£16,328.00 (ex VAT)

£19,593.60 (inc VAT)

Earn 16328 points

Contact us for delivery date

Customers also viewed

Fluke ii1050 Acoustic Imager

The Fluke ii1050 Acoustic Imager helps industrial maintenance and reliability teams locate faults in compressed air, gas and vacuum systems. It uses an array of 202 microphones to detect sound and display its source over a live camera image. With a frequency range of 2 kHz to 100 kHz and a detection distance of up to 150 metres, engineers can inspect equipment from a safe distance. This makes it easier to find leaks, detect electrical faults and check machinery during routine maintenance.

Built for a range of inspection tasks, the Fluke ii1050 Acoustic Imager combines several fault-finding tools in one unit. LeakQ mode estimates leak size, leak rate and related energy costs, helping teams decide which repairs to carry out first. PDQ Mode detects partial discharge, estimates discharge probability and shows real-time PRPD patterns, while MecQ helps identify bearing defects, friction, air turbulence and vibration. The camera also supports thermal inspection with the Fluke TC03A iSee Thermal Camera Attachment and air-tightness checks using the Fluke SB140 SoundBeacon.

Clear images and simple controls help users work through inspections with less effort. The Fluke ii1050 Acoustic Imager features a 7-inch anti-glare touchscreen, a 13 MP visible-light camera and 128 GB of storage. Users can tag assets, add notes, set action priorities and generate reports directly on the device. With a rechargeable battery system providing more than seven hours of operation using two batteries, the instrument supports longer inspection sessions and helps teams turn fault findings into repair actions.

 

Key Benefits
  • Locate compressed air, gas and vacuum leaks using a live acoustic image overlaid on a visible-light image.
  • Inspect equipment from distances of up to 150 metres, depending on ambient conditions.
  • Estimate leak rates and related energy costs to help prioritise maintenance work.
  • Identify partial discharge sources and assess discharge probability using PDQ Mode.
  • Investigate bearing defects, friction, air turbulence and vibration with MecQ.
  • View inspection images clearly on the 7-inch anti-glare touchscreen, including in sunlight.
  • Capture images and videos to document faults and support maintenance records.
  • Record asset details, inspection notes, repair priorities and actions directly on the device.
  • Generate inspection reports without transferring results to another device.
  • Use the compatible thermal camera attachment and SoundBeacon for further inspection tasks.

 

Common Applications

Fluke ii1050 Acoustic Imager is suitable for a range of testing, maintenance and inspection tasks, including:

  • Locating compressed air leaks in industrial equipment and systems.
  • Detecting gas leaks during maintenance inspections.
  • Finding leaks in vacuum systems.
  • Identifying partial discharge in electrical assets.
  • Evaluating electrical assets using real-time PRPD patterns.
  • Investigating bearing defects and mechanical friction.
  • Locating abnormal vibration and air turbulence in machinery.
  • Estimating leak rates and associated energy costs.
  • Checking air tightness using the Fluke SB140 SoundBeacon.
  • Carrying out thermal inspections with the compatible Fluke TC03A iSee Thermal Camera Attachment.

 

Why Choose This Model?

The Fluke ii1050 Acoustic Imager offers a wider frequency range and longer maximum detection distance than the ii500 and ii1030, while adding dedicated PDQ Mode and MecQ functions. Its 202-microphone array, 13 MP camera and on-device reporting make it a strong choice for teams carrying out leak detection, electrical inspections and mechanical fault finding.

Fluke ii1050 Acoustic Imager

The Fluke ii1050 Acoustic Imager helps industrial maintenance and reliability teams locate faults in compressed air, gas and vacuum systems. It uses an array of 202 microphones to detect sound and display its source over a live camera image. With a frequency range of 2 kHz to 100 kHz and a detection distance of up to 150 metres, engineers can inspect equipment from a safe distance. This makes it easier to find leaks, detect electrical faults and check machinery during routine maintenance.

Built for a range of inspection tasks, the Fluke ii1050 Acoustic Imager combines several fault-finding tools in one unit. LeakQ mode estimates leak size, leak rate and related energy costs, helping teams decide which repairs to carry out first. PDQ Mode detects partial discharge, estimates discharge probability and shows real-time PRPD patterns, while MecQ helps identify bearing defects, friction, air turbulence and vibration. The camera also supports thermal inspection with the Fluke TC03A iSee Thermal Camera Attachment and air-tightness checks using the Fluke SB140 SoundBeacon.

Clear images and simple controls help users work through inspections with less effort. The Fluke ii1050 Acoustic Imager features a 7-inch anti-glare touchscreen, a 13 MP visible-light camera and 128 GB of storage. Users can tag assets, add notes, set action priorities and generate reports directly on the device. With a rechargeable battery system providing more than seven hours of operation using two batteries, the instrument supports longer inspection sessions and helps teams turn fault findings into repair actions.

 

Key Benefits
  • Locate compressed air, gas and vacuum leaks using a live acoustic image overlaid on a visible-light image.
  • Inspect equipment from distances of up to 150 metres, depending on ambient conditions.
  • Estimate leak rates and related energy costs to help prioritise maintenance work.
  • Identify partial discharge sources and assess discharge probability using PDQ Mode.
  • Investigate bearing defects, friction, air turbulence and vibration with MecQ.
  • View inspection images clearly on the 7-inch anti-glare touchscreen, including in sunlight.
  • Capture images and videos to document faults and support maintenance records.
  • Record asset details, inspection notes, repair priorities and actions directly on the device.
  • Generate inspection reports without transferring results to another device.
  • Use the compatible thermal camera attachment and SoundBeacon for further inspection tasks.

 

Common Applications

Fluke ii1050 Acoustic Imager is suitable for a range of testing, maintenance and inspection tasks, including:

  • Locating compressed air leaks in industrial equipment and systems.
  • Detecting gas leaks during maintenance inspections.
  • Finding leaks in vacuum systems.
  • Identifying partial discharge in electrical assets.
  • Evaluating electrical assets using real-time PRPD patterns.
  • Investigating bearing defects and mechanical friction.
  • Locating abnormal vibration and air turbulence in machinery.
  • Estimating leak rates and associated energy costs.
  • Checking air tightness using the Fluke SB140 SoundBeacon.
  • Carrying out thermal inspections with the compatible Fluke TC03A iSee Thermal Camera Attachment.

 

Why Choose This Model?

The Fluke ii1050 Acoustic Imager offers a wider frequency range and longer maximum detection distance than the ii500 and ii1030, while adding dedicated PDQ Mode and MecQ functions. Its 202-microphone array, 13 MP camera and on-device reporting make it a strong choice for teams carrying out leak detection, electrical inspections and mechanical fault finding.

Product Comparison
Feature Fluke ii500 Fluke ii1030 Fluke ii1050
Microphones 64 202 202
Frequency range 2–52 kHz 2–64 kHz 2–100 kHz
Detection distance 0.5 to >70 m 0.5 to >100 m 0.5 to >150 m
Camera resolution 0.3 MP 13 MP 13 MP
Zoom None 3× digital 3× digital
Display 7-inch backlit LCD 7-inch anti-glare LCD 7-inch anti-glare LCD
Image storage 20 GB 110 GB 110 GB
LeakQ Leak size scale Size, rate and cost Size, rate and cost
PDQ Mode No No Yes
MecQ No No Yes
Battery operation 6 hours >7 hours (2 batteries) >7 hours (2 batteries)
Weight 2.1 kg 1.2 kg 1.2 kg
Ingress protection IP40 IP54 IP54

 

General Specifications
Specification Details
Product type Acoustic imaging camera
Model Fluke ii1050
Acoustic sensor array 202 MEM microphones
Acoustic imaging SoundMap acoustic imaging overlay
Visible-light camera 13 MP
Digital zoom 3×
Display 7-inch anti-glare LCD, sunlight readable
Display backlight Yes
Display resolution 1280 × 800 pixels
Touchscreen Capacitive
Image storage capacity 110 GB
Total storage 128 GB
Image format Blended visible-light and SoundMap JPG
Video format Blended visible-light and SoundMap MP4
Maximum video length Up to 5 minutes
Data transfer USB-C
USB connections 2 × USB-C
Wireless connectivity Wi-Fi
Acoustic display modes Multiple sound sources, selectable frequency bands and acoustic overlays
Reporting On-device reporting for PDQ, LeakQ, PDQ+Ti and LeakQ+Ti modes
Asset identification Text input and automatic QR code-based asset ID identification
Photo notes Up to 4 photo notes
Inspection status As left, As found and Undetermined
Action annotation Action requirement, priority and notes
Protection rating IP54
Electrical safety IEC 61010-1, Pollution Degree 2
Electromagnetic compatibility IEC 61326-1, industrial electromagnetic environment; CISPR 11 Group 1, Class A
Radio Equipment Directive 2014/53/EU compliant
RoHS compliance Yes
Warranty 2 years

 

Measurement and Accuracy Specifications
Specification Details
Frequency band 2 kHz to 100 kHz
Detection distance 0.5 m to >150 m (1.6 ft to >492 ft)
Acoustic field of view 64° × 48° typical
Nominal frame rate 25 FPS
Visible-light field of view 64° × 48° typical
Camera focus 50 cm to infinity
Acoustic measurement range at 20 kHz -10.4 to 122 dB SPL
Acoustic measurement range at 25 kHz -24.7 to 122 dB SPL
Acoustic measurement range at 31.5 kHz -13 to 122 dB SPL
Acoustic measurement range at 40 kHz -10.7 to 122 dB SPL
Acoustic measurement range at 50 kHz 8 to 122 dB SPL
Maximum dB gain Automatic or user-selectable maximum dB
Frequency band selection User-defined presets or manual entry
Acoustic high-frequency mode Yes
Multiple acoustic sources Multi Source
Acoustic profiles Preset capture profiles
Acoustic trend graphs Frequency and dB scale
Acoustic colour palettes Grayscale, Ironbow and Blue-Red
Overlay transparency 1–100%
Grayscale mode Yes
LeakQ measurement Leak size scale (1–10), leak rate and cost estimation
PDQ Mode Partial discharge source identification, discharge probability estimation and real-time PRPD patterns
MecQ Mechanical fault identification, including bearing defects, friction, vibration and air turbulence
Beacon mode Compatible with Fluke SB140 SoundBeacon for air-tightness detection
Thermal mode Compatible with Fluke TC03A iSee Thermal Camera Attachment

 

Mechanical and General Information
Specification Details
Dimensions (H × W × L) 235 × 154 × 46 mm
Weight including battery 1.2 kg (2.6 lb)
Operating temperature -10°C to 45°C
Storage temperature -20°C to 70°C, without batteries installed
Relative humidity 10–95% RH, non-condensing
Operating altitude Up to 2000 m
Storage altitude Up to 12000 m
Battery type Rechargeable, field-replaceable lithium-ion battery
Battery model RRC2040
Battery operating time More than 7 hours (2 × 3.5 hours)
Battery charging time Less than 3 hours
Charging system Internal USB-C charging
Charger kit 65 W wall charger, USB-C cable and country-specific connectors
Tripod connection 1/4-inch-20
User controls Capacitive touchscreen with user-selectable acoustic settings
Carrying accessories Hard case, hand strap and neck strap
Self-diagnostic notification Microphone array health test
Supported languages Arabic, Dutch, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Simplified Chinese, Spanish, Swedish and Traditional Chinese
Fluke Premium Care Premium Care Standard; configurations with one-year and three-year coverage options available

 

Specification Notes
  • The stated detection distance depends on ambient conditions and may exceed 150 metres under suitable conditions.
  • Acoustic measurement limits vary with frequency. The measurement ranges shown are typical values expressed in dB SPL.
  • Thermal inspection requires the compatible Fluke TC03A iSee Thermal Camera Attachment. Air-tightness detection with Beacon mode uses the Fluke SB140 SoundBeacon.
What’s Included
  • Fluke ii1050 Acoustic Imaging Camera
  • Hard case
  • Hand strap
  • Neck strap
  • 2 × RRC2040 battery packs
  • Charger kit with 65 W wall charger, USB-C cable and country-specific connectors

Available configurations also offer the Fluke TC03A iSee Thermal Camera Attachment, Fluke SB140 SoundBeacon and Fluke Premium Care coverage options.

Frequently Asked Questions
What is the Fluke ii1050 Acoustic Imager used for?

The Fluke ii1050 Acoustic Imager helps industrial maintenance and reliability teams detect compressed air, gas and vacuum leaks, locate electrical partial discharge and identify mechanical faults. It uses acoustic imaging to show the source of abnormal sounds over a visible-light camera image.

What is the maximum detection distance of the Fluke ii1050?

The Fluke ii1050 has a detection range from 0.5 metres to more than 150 metres (492 feet), depending on ambient conditions. This allows engineers to inspect equipment from a distance without needing to approach every potential fault.

Can the Fluke ii1050 detect electrical partial discharge?

Yes. The Fluke ii1050 includes PDQ Mode, which identifies partial discharge sources, estimates discharge probability and displays real-time phase-resolved partial discharge (PRPD) patterns to help engineers assess electrical assets.

Can the Fluke ii1050 identify mechanical faults?

Yes. Its MecQ function helps maintenance teams identify mechanical issues such as bearing defects, friction, vibration and air turbulence before these problems become more obvious through other signs.

Does the Fluke ii1050 measure compressed air leak rates?

Yes. LeakQ mode provides a leak size scale from 1 to 10 and estimates leak rate and associated energy costs. These results help maintenance teams assess leaks and prioritise repair work.

What is the frequency range of the Fluke ii1050?

The Fluke ii1050 operates across a frequency range of 2 kHz to 100 kHz using an array of 202 MEM microphones. Users can select frequency bands manually or use preset capture profiles to suit different inspection tasks.

Can the Fluke ii1050 carry out thermal inspections?

Yes. The Fluke ii1050 supports thermal inspection when used with the compatible Fluke TC03A iSee Thermal Camera Attachment. This enables thermal, acoustic and visible-light inspection within a single workflow when the appropriate configuration is selected.

Can the Fluke ii1050 be used for air-tightness testing?

Yes. The Fluke ii1050 supports Beacon mode and works with the Fluke SB140 SoundBeacon for air-tightness detection. The SoundBeacon is available as part of selected configurations.

Does the Fluke ii1050 record images and videos?

Yes. The Fluke ii1050 captures photographs in JPG format and videos in MP4 format, combining visible-light images with the SoundMap acoustic overlay. Video recordings can last up to five minutes, and the instrument provides 110 GB of image storage.

Can the Fluke ii1050 generate inspection reports?

Yes. The Fluke ii1050 supports on-device reporting, allowing users to record asset details, add photo notes, set repair priorities and document inspection findings. Reporting supports PDQ, LeakQ, PDQ+Ti and LeakQ+Ti modes.

How long does the Fluke ii1050 battery last?

The Fluke ii1050 provides more than seven hours of combined operation using two rechargeable lithium-ion batteries, with each battery providing approximately 3.5 hours. The batteries are field-replaceable, and charging takes less than three hours using the internal USB-C charging system.

What is the difference between the Fluke ii1050 and ii1030?

Both instruments feature 202 microphones, a 13 MP visible-light camera and a 7-inch anti-glare touchscreen. However, the Fluke ii1050 extends the frequency range to 100 kHz compared with 64 kHz on the ii1030, and increases the detection distance from more than 100 metres to more than 150 metres. The ii1050 also adds PDQ Mode for partial discharge analysis and MecQ for mechanical fault identification.

Is the Fluke ii1050 suitable for industrial environments?

Yes. The Fluke ii1050 has an IP54 ingress protection rating and operates at temperatures from -10°C to 45°C. It also features a sunlight-readable anti-glare touchscreen and complies with IEC 61010-1, Pollution Degree 2, and IEC 61326-1 requirements for industrial electromagnetic environments.

What accessories are included with the Fluke ii1050?

The Fluke ii1050 comes with a hard case, hand strap, neck strap, two RRC2040 battery packs and a charger kit containing a 65 W wall charger, USB-C cable and country-specific connectors. Configurations featuring the Fluke TC03A iSee Thermal Camera Attachment, Fluke SB140 SoundBeacon and Fluke Premium Care are also available.

Ask a question

Ask a question | Product pages