Kane 458s IAQ HVACR Flue Gas Analyser

  • Designed for HVACR and combustion engineers
  • Combines flue gas, IAQ and HVACR testing
  • Measures O2, CO2, CO, H2 and pressure
  • KANE LINK and KANE LIVE app connectivity

£1,299.00 (ex VAT)

£1,558.80 (inc VAT)

Earn 1299 points

Usually ships In 3 to 5 working days

Why buy from Test4Less?

  • Designed for HVACR and combustion engineers
  • Combines flue gas, IAQ and HVACR testing
  • Measures O2, CO2, CO, H2 and pressure
  • KANE LINK and KANE LIVE app connectivity
Free Shipping

Spend over £100 on any new goods order and receive automatic free shipping

Rewards

Points make purchases! For every £1 spent, earn back 1p that can be spent on any future new goods purchase

Our Price Promise

We offer a Price Match Promise! Find an equivalent tester for a cheaper price on a competitor site, and we’ll do our best to match it

Express Delivery & Calibration

Express Delivery is currently unavailable for customers wishing to add calibration to their New Goods order. For more information, visit our Delivery Information page. 

£1,299.00 (ex VAT)

£1,558.80 (inc VAT)

Earn 1299 points

Usually ships In 3 to 5 working days

Customers also viewed

Kane 458s IAQ HVACR Flue Gas Analyser

The Kane 458s IAQ HVACR Flue Gas Analyser combines combustion analysis, indoor air quality testing and HVACR measurement in one handheld instrument. It measures O2, CO2, CO and H2 as standard, with an optional NO sensor available for NOx testing. Integrated IAQ CO2 measurement also supports room migration testing, appliance sweep testing and indoor air quality checks.

Engineers can use the analyser for heating, cooling, refrigeration, ventilation and combustion work without relying on separate instruments for each core task. KANE LINK compatibility supports wireless probes for refrigeration diagnostics, airflow, temperature, humidity and pressure measurements, while connection to the KANE LIVE app provides wireless connectivity. The instrument also calculates combustion efficiency, excess air, CO/CO2 ratio and HVACR superheat and subcool values.

Suitable for domestic and commercial work, the Kane 458s IAQ HVACR Flue Gas Analyser supports testing of commercial direct-fired and flueless appliances as well as Type C sealed appliances, Type B open-flue boilers and Type A cookers, space heaters and water heaters. It is certified to EN50379 and EN5043 for O2, CO, flue gas and IAQ testing and supports 12 standard fuels plus five user fuels and 40 refrigerants. Data logging, report generation, KANE LOCK security and compatibility with the optional KANE-IRP3 printer add useful support for field testing and record keeping.

 

Key Benefits
  • Combines flue gas, indoor air quality and HVACR testing in one handheld analyser.
  • Integrated IAQ CO2 measurement supports timed room migration and appliance sweep tests.
  • KANE LINK compatibility enables wireless use with suitable probes and accessories.
  • KANE LIVE app connectivity supports wireless access to analyser data.
  • Calculates combustion efficiency, excess air and CO/CO2 ratio to support combustion assessment.
  • Calculates refrigeration superheat and subcool values for HVACR diagnostic work.
  • Supports data logging and report generation for recording test results.
  • KANE LOCK can automatically disable a stolen analyser.
  • Optional KANE-IRP3 printer provides a way to print results on site.

 

Common Applications

Kane 458s IAQ HVACR Flue Gas Analyser is suitable for a range of testing, maintenance and inspection tasks, including:

  • Combustion and flue gas analysis.
  • Indoor air quality CO and CO2 testing.
  • Room migration timed testing for CO and CO2.
  • Appliance timed sweep testing for CO and CO2.
  • Commercial direct-fired and flueless appliance testing.
  • Type C sealed appliance testing.
  • Type B open-flue boiler testing.
  • Type A cooker, space heater and water heater testing.
  • Air conditioning and refrigeration superheat and subcool testing.
  • Ventilation airflow, temperature and humidity testing with suitable optional accessories.

 

Why Choose This Model?

The Kane 458s IAQ adds integrated indoor air quality capability to the KANE 458s feature set, while retaining refrigeration-side, air-side and EVAC testing, differential pressure measurement, KANE LINK connectivity and sensor upgrade support. Compared with the listed KANE 158, 258 and 358 models, it also adds IAQ CO2 measurement and AC and refrigeration functions.

Kane 458s IAQ HVACR Flue Gas Analyser

The Kane 458s IAQ HVACR Flue Gas Analyser combines combustion analysis, indoor air quality testing and HVACR measurement in one handheld instrument. It measures O2, CO2, CO and H2 as standard, with an optional NO sensor available for NOx testing. Integrated IAQ CO2 measurement also supports room migration testing, appliance sweep testing and indoor air quality checks.

Engineers can use the analyser for heating, cooling, refrigeration, ventilation and combustion work without relying on separate instruments for each core task. KANE LINK compatibility supports wireless probes for refrigeration diagnostics, airflow, temperature, humidity and pressure measurements, while connection to the KANE LIVE app provides wireless connectivity. The instrument also calculates combustion efficiency, excess air, CO/CO2 ratio and HVACR superheat and subcool values.

Suitable for domestic and commercial work, the Kane 458s IAQ HVACR Flue Gas Analyser supports testing of commercial direct-fired and flueless appliances as well as Type C sealed appliances, Type B open-flue boilers and Type A cookers, space heaters and water heaters. It is certified to EN50379 and EN5043 for O2, CO, flue gas and IAQ testing and supports 12 standard fuels plus five user fuels and 40 refrigerants. Data logging, report generation, KANE LOCK security and compatibility with the optional KANE-IRP3 printer add useful support for field testing and record keeping.

 

Key Benefits
  • Combines flue gas, indoor air quality and HVACR testing in one handheld analyser.
  • Integrated IAQ CO2 measurement supports timed room migration and appliance sweep tests.
  • KANE LINK compatibility enables wireless use with suitable probes and accessories.
  • KANE LIVE app connectivity supports wireless access to analyser data.
  • Calculates combustion efficiency, excess air and CO/CO2 ratio to support combustion assessment.
  • Calculates refrigeration superheat and subcool values for HVACR diagnostic work.
  • Supports data logging and report generation for recording test results.
  • KANE LOCK can automatically disable a stolen analyser.
  • Optional KANE-IRP3 printer provides a way to print results on site.

 

Common Applications

Kane 458s IAQ HVACR Flue Gas Analyser is suitable for a range of testing, maintenance and inspection tasks, including:

  • Combustion and flue gas analysis.
  • Indoor air quality CO and CO2 testing.
  • Room migration timed testing for CO and CO2.
  • Appliance timed sweep testing for CO and CO2.
  • Commercial direct-fired and flueless appliance testing.
  • Type C sealed appliance testing.
  • Type B open-flue boiler testing.
  • Type A cooker, space heater and water heater testing.
  • Air conditioning and refrigeration superheat and subcool testing.
  • Ventilation airflow, temperature and humidity testing with suitable optional accessories.

 

Why Choose This Model?

The Kane 458s IAQ adds integrated indoor air quality capability to the KANE 458s feature set, while retaining refrigeration-side, air-side and EVAC testing, differential pressure measurement, KANE LINK connectivity and sensor upgrade support. Compared with the listed KANE 158, 258 and 358 models, it also adds IAQ CO2 measurement and AC and refrigeration functions.

Product Comparison
Feature KANE 158 KANE 258 KANE 358 KANE 458s KANE 458s IAQ KANE 958
Differential temperature Yes Yes Yes Yes Yes Yes
KANE LIVE app connectivity Yes Yes Yes Yes Yes Yes
2-minute appliance sweep test – – Yes Yes Yes Yes
KANE LINK – – – Yes Yes Yes
Indoor air quality – – – Optional Yes Optional
High CO 0-10,000 ppm with H2 compensation – – Yes Yes Yes Yes
Differential pressure – Yes, with KANE LIVE app Yes Yes Yes Yes, ±160 mbar
AC & refrigeration – – – Yes Yes –
Optional NO measurement – – – 600 ppm 600 ppm 5,000 ppm
CO / CO2 ratio calculation Yes Yes Yes Yes Yes Yes
Combustion efficiency calculation Yes Yes Yes Yes Yes Yes

 

General Specifications
Specification Details
Product type Flue gas, indoor air quality and HVACR analyser
Display 6-line LCD display
Data hold Yes
Wireless connectivity KANE LINK compatible and connects to the KANE LIVE app
Data functions Data logging and report generation
Security function KANE LOCK automatically disables a stolen analyser
Certification EN50379 and EN5043 certified for O2, CO, flue gas and IAQ
Fuel support 12 standard fuels including Natural Gas, LPG, Butane, Propane, Light Oil and Heavy Oil, plus 5 user fuels
Refrigerant support 40 refrigerants including R22, R32, R134a, R290 and R410A
Printer compatibility Optional KANE-IRP3 printer

 

Measurement and Accuracy Specifications
Specification Details
O2 measurement 0-21%
IAQ CO2 measurement 0-9,999 ppm
CO measurement 0-10,000 ppm with H2 compensation
H2 measurement Yes
NO measurement 0-600 ppm optional
Differential temperature -20 to +1350°C with suitable probes
Differential pressure -80 to +80 mbar
Airflow 1.1-20 m/s with KANE-DTHA2 option
Temperature with KANE-DTHA2 -20 to +50°C
Relative humidity with KANE-DTHA2 0.1-99%
Room CO with KANE79 option 0-999 ppm
Calculated values CO2 flue gas, CO/CO2 ratio, excess air, combustion efficiency, NOx with optional NO sensor, and A/C & refrigeration superheat and subcool

 

Mechanical and General Information
Specification Details
Body construction Hard plastic body
Controls Tactile rotary dial design
Power supply 3 rechargeable batteries
Charging USB charger
Carrying method MSC00237 protective case and 14102/2 carry bag
Probe connection CP2 flue gas probe supplied

 

Specification Notes
  • NO measurement up to 600 ppm requires the optional NO sensor.
  • Airflow, -20 to +50°C temperature and 0.1-99% RH measurements require the optional KANE-DTHA2.
  • Differential temperature up to +1350°C requires suitable probes, while room CO measurement to 999 ppm requires the optional KANE79 CO monitor.
What’s Included
  • Kane 458s IAQ HVACR Flue Gas Analyser
  • CP2 flue gas probe
  • 3 rechargeable batteries
  • USB charger
  • MSC00237 protective case
  • 14102/2 carry bag
  • KANE-IRP3 printer option
  • KANE-DTHA2 option for airflow, temperature and relative humidity measurements
  • KANE79 CO monitor option for room CO measurement
  • Optional NO sensor for NOx testing

Ask a question