Martindale EPAT2100 Dual Voltage Manual PAT Tester

  • Tests 110V and 230V appliances
  • 25A, 8A and 200mA earth bond testing
  • Built-in flash test up to 3kV AC output
  • Run current and leakage measurement
Free Shipping

Spend over £100 on any new goods order and receive automatic free shipping

Rewards

Points make purchases! For every £1 spent, earn back 1p that can be spent on any future new goods purchase

Our Price Promise

We offer a Price Match Promise! Find an equivalent tester for a cheaper price on a competitor site, and we’ll do our best to match it

Express Delivery & Calibration

Express Delivery is currently unavailable for customers wishing to add calibration to their New Goods order. For more information, visit our Delivery Information page. 

£947.70 (ex VAT)

£1,137.24 (inc VAT)

Earn 947 points

Usually ships In 3 to 5 working days
  • Tests 110V and 230V appliances
  • 25A, 8A and 200mA earth bond testing
  • Built-in flash test up to 3kV AC output
  • Run current and leakage measurement
Free Shipping

Spend over £100 on any new goods order and receive automatic free shipping

Rewards

Points make purchases! For every £1 spent, earn back 1p that can be spent on any future new goods purchase

Our Price Promise

We offer a Price Match Promise! Find an equivalent tester for a cheaper price on a competitor site, and we’ll do our best to match it

Express Delivery & Calibration

Express Delivery is currently unavailable for customers wishing to add calibration to their New Goods order. For more information, visit our Delivery Information page. 

£947.70 (ex VAT)

£1,137.24 (inc VAT)

Earn 947 points

Usually ships In 3 to 5 working days
Product Question
Name
Name
Plain text only. HTML is not allowed.
 

Martindale EPAT2100 Dual Voltage Manual PAT Tester

The Martindale EPAT2100 Dual Voltage Manual PAT Tester provides a simple and effective way to carry out portable appliance testing on both 110V and 230V equipment. Its one-button operation helps users complete routine inspections quickly and consistently. Clear test functions make it suitable for a wide range of workplace environments.

Designed for Class I and Class II appliance testing, this tester performs earth bond and insulation resistance checks while also offering run current, leakage current and flash testing. It supports both standard and more demanding testing requirements. As a result, maintenance teams can complete several test procedures with a single instrument.

Dual Voltage Testing Capability

Unlike single-voltage alternatives, the Martindale EPAT2100 Dual Voltage Manual PAT Tester operates from either a 110V or 230V supply. This allows testing of equipment commonly found on construction sites, industrial facilities and commercial premises. It also enables run current and leakage tests without requiring an external power source.

High and low current earth bond testing adds further flexibility. Users can select 25A or 8A for standard earth continuity testing, while the 200mA option allows safer testing of sensitive IT and electronic equipment. This helps reduce the risk of damage during inspection procedures.

Comprehensive PAT Test Functions

Built-in flash testing expands the capability of the unit beyond standard PAT requirements. The tester can perform flash tests at 1.5kV AC for Class I appliances and 3.0kV AC for Class II appliances. Dedicated indicators provide clear status information during testing and help improve user confidence.

For added convenience, the unit includes a lead testing facility for IEC power leads and is supplied with accessories for testing mains extension leads. Two set types are available, allowing users to select the package best suited to their testing requirements. The compact design and straightforward controls make the tester easy to transport and operate in busy working environments.

 

Key Features

  • Tests both 110V and 230V appliances
  • One-button manual PAT testing operation
  • Suitable for Class I and Class II appliances
  • Performs insulation resistance testing
  • Performs earth continuity testing
  • Provides run current measurement
  • Measures earth leakage current
  • Integrated flash testing function
  • Supports sensitive equipment testing at 200mA
  • Built-in IEC lead testing capability
  • Supplied with accessories for extension lead testing
  • Mains powered from 110V or 230V supplies
  • Displays test values during operation
  • Automatic test mode for straightforward use
  • Two set types available to suit application requirements

 

Technical Specifications

Manufacturer Martindale Electric
Model EPAT2100
Product name Martindale EPAT2100 Dual Voltage Manual PAT Tester
Manufacturer part code EPAT2100
Supply voltage 110V / 230V ±10%
Supply frequency 50/60Hz
Power consumption 10VA / 220VA
Appliance types Class I and Class II
Insulation test voltage 500V DC -0% +20%
Insulation test range 0 to 19.9MΩ
Insulation accuracy ±5% of reading ±1 digit
Insulation short circuit current 1.5mA DC nominal
Earth continuity test currents 200mA, 8A and 25A
Run current range 0 to 19.9A
Run current accuracy ±10% of reading ±1 digit
Earth leakage range 0 to 19.9mA
Earth leakage accuracy ±10% of reading ±1 digit
Flash test voltage Class I 1.5kV AC
Flash test voltage Class II 3.0kV AC
Flash test display range 0 to 19.9mA AC
Flash test usable range 0 to 3.5mA AC
Flash test trip current 4mA nominal
Flash test accuracy ±5% of reading ±1 digit
Earth continuity lead length 1.5m
Mains socket 240V 13A to BS1363
110V socket 110V 16A to BS4343
Flash socket 4mm high safety socket
Indicators Neon lamp, red LED over-temperature indicator and polarity LEDs
Compliance BS EN 61010-1
Dimensions 330 x 263 x 144mm
Weight 5.1kg
EAN 5036162184482
110V adaptor included Yes, TL150 adaptor supplied
Warranty Not specified

 

Comparison Table

EPAT1600 EPAT2100 MPATPLUS
Class I / II Test
Lead Test With accessory
Test Values Displayed
Test Mode Auto Auto Auto / Manual
Run Test
Earth Continuity Test Current 200mA / 8A / 25A 200mA / 8A / 25A 200mA / 25A
Insulation Test Voltage 500V 500V 500V
110V Appliances
Flash Test 1.5kV / 3kV 1.5kV / 3kV
Memory 1000 results for download
Supply 230V 230V / 110V 230V / 110V

 

Document Downloads

pdf
pdf

 

What’s Included

  • Martindale EPAT2100 Dual Voltage Manual PAT Tester
  • TL150 110V adaptor
  • Earth continuity lead
  • IEC lead testing facility
  • Accessories for extension lead testing

 

pdf
pdf

Martindale EPAT2100 Dual Voltage Manual PAT Tester

The Martindale EPAT2100 Dual Voltage Manual PAT Tester provides a simple and effective way to carry out portable appliance testing on both 110V and 230V equipment. Its one-button operation helps users complete routine inspections quickly and consistently. Clear test functions make it suitable for a wide range of workplace environments.

Designed for Class I and Class II appliance testing, this tester performs earth bond and insulation resistance checks while also offering run current, leakage current and flash testing. It supports both standard and more demanding testing requirements. As a result, maintenance teams can complete several test procedures with a single instrument.

Dual Voltage Testing Capability

Unlike single-voltage alternatives, the Martindale EPAT2100 Dual Voltage Manual PAT Tester operates from either a 110V or 230V supply. This allows testing of equipment commonly found on construction sites, industrial facilities and commercial premises. It also enables run current and leakage tests without requiring an external power source.

High and low current earth bond testing adds further flexibility. Users can select 25A or 8A for standard earth continuity testing, while the 200mA option allows safer testing of sensitive IT and electronic equipment. This helps reduce the risk of damage during inspection procedures.

Comprehensive PAT Test Functions

Built-in flash testing expands the capability of the unit beyond standard PAT requirements. The tester can perform flash tests at 1.5kV AC for Class I appliances and 3.0kV AC for Class II appliances. Dedicated indicators provide clear status information during testing and help improve user confidence.

For added convenience, the unit includes a lead testing facility for IEC power leads and is supplied with accessories for testing mains extension leads. Two set types are available, allowing users to select the package best suited to their testing requirements. The compact design and straightforward controls make the tester easy to transport and operate in busy working environments.

 

Key Features

  • Tests both 110V and 230V appliances
  • One-button manual PAT testing operation
  • Suitable for Class I and Class II appliances
  • Performs insulation resistance testing
  • Performs earth continuity testing
  • Provides run current measurement
  • Measures earth leakage current
  • Integrated flash testing function
  • Supports sensitive equipment testing at 200mA
  • Built-in IEC lead testing capability
  • Supplied with accessories for extension lead testing
  • Mains powered from 110V or 230V supplies
  • Displays test values during operation
  • Automatic test mode for straightforward use
  • Two set types available to suit application requirements

 

Technical Specifications

Manufacturer Martindale Electric
Model EPAT2100
Product name Martindale EPAT2100 Dual Voltage Manual PAT Tester
Manufacturer part code EPAT2100
Supply voltage 110V / 230V ±10%
Supply frequency 50/60Hz
Power consumption 10VA / 220VA
Appliance types Class I and Class II
Insulation test voltage 500V DC -0% +20%
Insulation test range 0 to 19.9MΩ
Insulation accuracy ±5% of reading ±1 digit
Insulation short circuit current 1.5mA DC nominal
Earth continuity test currents 200mA, 8A and 25A
Run current range 0 to 19.9A
Run current accuracy ±10% of reading ±1 digit
Earth leakage range 0 to 19.9mA
Earth leakage accuracy ±10% of reading ±1 digit
Flash test voltage Class I 1.5kV AC
Flash test voltage Class II 3.0kV AC
Flash test display range 0 to 19.9mA AC
Flash test usable range 0 to 3.5mA AC
Flash test trip current 4mA nominal
Flash test accuracy ±5% of reading ±1 digit
Earth continuity lead length 1.5m
Mains socket 240V 13A to BS1363
110V socket 110V 16A to BS4343
Flash socket 4mm high safety socket
Indicators Neon lamp, red LED over-temperature indicator and polarity LEDs
Compliance BS EN 61010-1
Dimensions 330 x 263 x 144mm
Weight 5.1kg
EAN 5036162184482
110V adaptor included Yes, TL150 adaptor supplied
Warranty Not specified

 

Comparison Table

EPAT1600 EPAT2100 MPATPLUS
Class I / II Test
Lead Test With accessory
Test Values Displayed
Test Mode Auto Auto Auto / Manual
Run Test
Earth Continuity Test Current 200mA / 8A / 25A 200mA / 8A / 25A 200mA / 25A
Insulation Test Voltage 500V 500V 500V
110V Appliances
Flash Test 1.5kV / 3kV 1.5kV / 3kV
Memory 1000 results for download
Supply 230V 230V / 110V 230V / 110V

 

Document Downloads

pdf
pdf

 

What’s Included

  • Martindale EPAT2100 Dual Voltage Manual PAT Tester
  • TL150 110V adaptor
  • Earth continuity lead
  • IEC lead testing facility
  • Accessories for extension lead testing

 

QUESTIONS