Martindale EPAT1600 Dual Voltage Manual PAT Tester
The Martindale EPAT1600 Dual Voltage Manual PAT Tester provides a quick and reliable way to carry out portable appliance testing on both 110V and 230V equipment. Its simple one-button operation helps users complete tests efficiently while still displaying clear measurement values. As a result, it is well suited to maintenance teams, facilities staff and contractors who need straightforward PAT testing.
Designed for everyday use, the unit supports Class I and Class II appliance testing with selectable earth continuity test currents. Users can choose 200mA for sensitive IT equipment or select 8A and 25A for higher current earth bond testing. In addition, the clear controls reduce setup time and make operation easy for routine inspections.
Dual Voltage Testing
Because the Martindale EPAT1600 Dual Voltage Manual PAT Tester works with both 110V and 230V appliances, it is suitable for a wide range of environments. From offices and schools to workshops and construction sites, the tester helps maintain electrical safety standards. Furthermore, the dual voltage capability removes the need for separate testing equipment.
The integrated lead testing function allows fast verification of IEC power leads and extension leads. When used with the supplied EX332 adaptor, users can identify common wiring faults such as phase and neutral reversal, phase open circuit and phase to neutral short conditions. Therefore, faults can be found quickly before equipment is returned to service.
Built for Practical Use
A durable hard carry case helps protect the instrument during transport and storage. The tester also displays measured values directly on screen, allowing users to review results immediately. As a result, testing can be completed efficiently in busy working environments.
Two different set types are available for the Martindale EPAT1600 Dual Voltage Manual PAT Tester, allowing users to choose the package that best suits their testing requirements. Each option retains the same core testing functions and simple manual operation. This makes the tester a flexible solution for organisations that require dependable PAT testing equipment.
Key Features
- Tests both 110V and 230V portable appliances
- Suitable for Class I and Class II appliance testing
- Simple one-button manual PAT testing operation
- Selectable 200mA earth continuity test for sensitive equipment
- High current earth bond testing at 8A
- High current earth bond testing at 25A
- 500V insulation resistance testing
- Displays measured test values on screen
- Built-in IEC lead testing capability
- Checks extension leads using the supplied adaptor
- Identifies common wiring faults in extension leads
- Supplied in a hard carry case
- Suitable for routine workplace electrical safety testing
- Simple rocker switch for selecting test current
Technical Specifications
| Manufacturer | Martindale Electric |
| Manufacturer part code | EPAT1600 |
| Product type | Dual voltage manual PAT tester |
| Supported appliance voltages | 110V and 230V |
| Test mode | Manual operation |
| Class testing | Class I and Class II |
| Insulation test voltage | 500V DC |
| Insulation test voltage tolerance | 0% to +20% |
| Insulation test short circuit current | 1.5mA DC nominal |
| Insulation resistance display range | 0MΩ to 19.9MΩ |
| Insulation resistance accuracy | ±5% of reading ±1 digit |
| Earth continuity test currents | 200mA DC, 8A AC and 25A AC |
| 25A continuity test specification | 25A AC nominal at 0.1Ω |
| 8A continuity test specification | 8A AC nominal at 0.1Ω |
| Earth continuity display range | 0Ω to 1.99Ω |
| Earth continuity accuracy | ±10% of reading ±2 digits |
| 200mA continuity open circuit voltage | 130mV DC nominal |
| Fuse test voltage | 6V AC nominal |
| Fuse test overrange threshold | 10kΩ nominal |
| Fuse test zero range threshold | 800kΩ nominal |
| Mains lead length | 1.7m fixed lead with 13A moulded plug |
| Earth continuity lead | 3m detachable lead with shrouded crocodile clip |
| IEC adaptor | 13A BS1363 plug to IEC320 connector |
| IEC adaptor length | 230mm |
| Mains socket | 230V 13A to BS1363 |
| 110V socket | 16A to BS4343 |
| Lead test socket | IEC320 |
| Housing material | ABS and polycarbonate |
| Supply voltage | 230V ±10% |
| Frequency | 50Hz to 60Hz |
| Power consumption | 10VA / 220VA |
| EMC compliance | BS EN 50081-1 and EN 50082-1 |
| Low voltage directive compliance | BS EN 61010-1 |
| Included adaptor | EX332 extension lead adaptor |
| Warranty | Not specified |
Comparison Table
| Feature | EPAT1600 | EPAT2100 |
| Class I / II Test | ✓ | ✓ |
| Lead Test | ✓ | ✓ |
| Test Values Displayed | ✓ | ✓ |
| Test Mode | Auto | Auto |
| Run Test | ✓ | ✓ |
| Earth Continuity Test Current | 200mA / 8A / 25A | 200mA / 8A / 25A |
| Insulation Test Voltage | 500V | 500V |
| 110V Appliances | ✓ | ✓ |
| Flash Test | – | 1.5kV / 3kV |
| Supply | 230V | 230V / 110V |
Document Downloads
What’s Included
- Martindale EPAT1600 Dual Voltage Manual PAT Tester
- TL66 bond lead
- EX332 230V plug to socket lead adaptor
- Instruction manual
- Hard carry case