Megger TPT420 Two-Pole Voltage Tester

SKU: AVO/TPT420
MPN: 1013-189
  • Built for electricians and electrical tests
  • Measures from 12 to 1000 V AC and 1500 V DC
  • Voltage indication works without batteries
  • Phase rotation and continuity test functions

£69.00 (ex VAT)

£82.80 (inc VAT)

Earn 69 points

In Stock - Express Delivery Available

Why buy from Test4Less?

  • Built for electricians and electrical tests
  • Measures from 12 to 1000 V AC and 1500 V DC
  • Voltage indication works without batteries
  • Phase rotation and continuity test functions
Free Shipping

Spend over £100 on any new goods order and receive automatic free shipping

Rewards

Points make purchases! For every £1 spent, earn back 1p that can be spent on any future new goods purchase

Our Price Promise

We offer a Price Match Promise! Find an equivalent tester for a cheaper price on a competitor site, and we’ll do our best to match it

Express Delivery & Calibration

Express Delivery is currently unavailable for customers wishing to add calibration to their New Goods order. For more information, visit our Delivery Information page. 

£69.00 (ex VAT)

£82.80 (inc VAT)

Earn 69 points

In Stock - Express Delivery Available

Customers also viewed

You may also like…

    • Fluke T130 Voltage & Continuity Tester
       Usually ships In 1 to 2 weeks

      Fluke T130 Voltage & Continuity Tester

      £102.00 (ex VAT)
      £122.40 (inc VAT)
      • Back lit LCD display with voltage measurement
      • Continuity test with audible and visual indication
      • Wear indicating test leads
      • Display hold function
      • Bright LED torch
    • Testo 755-2 Current-Voltage Tester
       Usually ships In 3 to 5 working days

      Testo 755-2 Current-Voltage Tester

      £127.50 (ex VAT)
      £153.00 (inc VAT)
      • Tests AC/DC voltage up to 1000 V
      • Single lead voltage detection
      • Detects phase rotation and polarity
      • Auto test parameter selection
    • Megger MPU690 Proving Unit
      In Stock - Express Delivery Available

      Megger MPU690 Proving Unit

      £79.00 (ex VAT)
      £94.80 (inc VAT)
      • 5 stepped voltage output from 50–690 V
      • Automatic probe-activated operation
      • Rugged case with magnetic base support
      • Long-lasting battery with LED indicators
    • Testo 755-1 Current Voltage Tester
       Usually ships In 3 to 5 working days

      Testo 755-1 Current Voltage Tester

      £106.00 (ex VAT)
      £127.20 (inc VAT)
      • Auto-selects parameters for fast testing
      • Measures AC/DC voltage and AC current
      • Interchangeable tips and integrated torch
      • IP64 rated for added protection
  • Built for electricians and electrical tests
  • Measures from 12 to 1000 V AC and 1500 V DC
  • Voltage indication works without batteries
  • Phase rotation and continuity test functions

Megger TPT420 Two-Pole Voltage Tester

Built for electricians and electrical engineers, the Megger TPT420 Two-Pole Voltage Tester provides AC and DC voltage measurement across low-voltage installations. Its LED and four-digit LCD displays indicate from 12 to 1000 V AC and 12 to 1500 V DC, while automatic polarity indication and a backlight support clear reading. A dangerous-voltage warning remains available when the batteries are exhausted, although this function must not be used for measurement purposes.

Beyond voltage testing, the instrument provides continuity indication from 0 to 500 kΩ, a diode test, single-pole phase testing and phase-rotation indication. Its phase-rotation function avoids crossing the test probes, while measurements between phase and earth are designed to remain below the tripping threshold of RCDs, RCBOs and safety breakers. An integrated LED torch assists in poorly lit environments, while the CAT IV 1000 V rating, IP64 housing and supplied GS38 shrouds support use under the stated electrical test conditions.

Key Benefits
  • LED and LCD displays provide stepped voltage indication and a digital reading
  • Dangerous-voltage warning remains available when the batteries are exhausted
  • Continuity testing provides both visual and acoustic indication
  • Simplified phase-rotation testing avoids crossing the test probes
  • Low input current helps avoid unintentional disconnection of RCD, RCBO and safety-breaker protected circuits
  • Single-pole phase testing provides an additional voltage-indication function
  • Automatic power control switches the tester on when a supported signal is detected
  • Integrated LED torch supports work in poorly lit environments
  • Self-test function checks that the batteries can power the tester correctly
  • CAT IV 1000 V rating and IP64 protection support use within the stated conditions

Common Applications

The Megger TPT420 is suitable for a range of electrical testing tasks, including:

  • AC voltage measurement
  • DC voltage measurement
  • Continuity testing
  • Testing within electrical installations
  • Automotive electrical testing
  • Fire alarm system testing
  • Solar and PV system testing

General Specifications
Specification Details
Product type Two-pole voltage tester
Display 13 LEDs and four-digit LCD
Backlight Automatic
Polarity indication Automatic LED indication for AC, positive DC and negative DC
Voltage indication without batteries Voltage warning LED operates when dangerous voltage is present, including when the batteries are exhausted; this function must not be used for measurement
Acoustic indication Sounder accompanies voltage and continuity indication; voltage threshold is approximately 38 V AC or 100 V DC
Single-pole phase test 100 to 1000 V AC at 50/60 Hz
Rotation field test 170 to 1000 V AC at 50/60 Hz, with left and right rotary-field indication
Diode test Visual and acoustic indication according to diode orientation
Auto-power-on Activates when continuity, AC or DC voltage above approximately 10 V, or a live phase at L2 is detected; also activates through the torch button
Auto-power-off Approximately 5 seconds after no signal is detected; torch switches off after approximately 10 seconds
Self-test Continuity LED and continuous audible tone confirm sufficient battery power when the probe tips are shorted together
Peak current Is <3.5 mA at 1000 V
Input current <3.5 mA at 690 V AC
<6 mA at 1500 V DC
Electrical measurement category CAT IV 1000 V
Safety standards IEC/EN 61243-3 and DIN VDE 0682-401
EMC standard EN 61326-1
Ingress protection IP64
Pollution degree 2
Power supply 2 x 1.5 V AAA batteries, IEC R03

Measurement and Accuracy Specifications
Measurement Function Range and Resolution Accuracy
AC voltage Range: 12 to 1000 V AC
Resolution: 1 V
Frequency range: 40 to 400 Hz
±3% ±5 dgt
DC voltage Range: 12 to 1500 V DC
Resolution: 1 V
Polarity: DC(±)
±3% ±5 dgt
LED voltage indication Nominal voltages: ±12, 24, 50, 120, 230, 400, 690 and 1000 V
Response time: <1 s at 100% of each nominal voltage
LED tolerances according to EN 61243-3
Continuity 0 to 500 kΩ
Visual and acoustic indication
No continuity measurement on the LCD
Threshold tolerance: +50%

Mechanical and General Information
Specification Details
Dimensions 67 mm (W) x 205 mm (L) x 19 mm (D)
Weight 180 g
Probe lead length 1.2 m
Operating temperature -5 to 40 °C, with no condensation
Storage temperature -20 to 70 °C, with no condensation
Humidity Maximum 85% RH
Maximum altitude Up to 2000 m
Probe features Main probe, remote probe, hand barriers, GS38 UK tips and Euro tips
Measurement light Integrated LED torch

Specification Notes
  • Datasheet specifications are stated at 23 °C ±5 °C and ≤80% RH
  • Measurement duty is 30 seconds on followed by a 240-second recovery period
  • Single-pole phase testing must not be the sole verification of a live circuit, and effective phase-rotation results require a three-phase four-wire system

What’s Included
  • Protective pouch, 2005-536
  • GS38 probe-tip shrouds
  • 2 x AAA batteries

Meta Description

Megger TPT420 Two-Pole Voltage Tester measures 12 to 1000 V AC and 12 to 1500 V DC, with phase rotation and continuity indication.

Reviews

There are no reviews yet.

Be the first to review “Megger TPT420 Two-Pole Voltage Tester”
Megger TPT420 Two-Pole Voltage Tester

Built for electricians and electrical engineers, the Megger TPT420 Two-Pole Voltage Tester provides AC and DC voltage measurement across low-voltage installations. Its LED and four-digit LCD displays indicate from 12 to 1000 V AC and 12 to 1500 V DC, while automatic polarity indication and a backlight support clear reading. A dangerous-voltage warning remains available when the batteries are exhausted, although this function must not be used for measurement purposes.

Beyond voltage testing, the instrument provides continuity indication from 0 to 500 kΩ, a diode test, single-pole phase testing and phase-rotation indication. Its phase-rotation function avoids crossing the test probes, while measurements between phase and earth are designed to remain below the tripping threshold of RCDs, RCBOs and safety breakers. An integrated LED torch assists in poorly lit environments, while the CAT IV 1000 V rating, IP64 housing and supplied GS38 shrouds support use under the stated electrical test conditions.

Key Benefits
  • LED and LCD displays provide stepped voltage indication and a digital reading
  • Dangerous-voltage warning remains available when the batteries are exhausted
  • Continuity testing provides both visual and acoustic indication
  • Simplified phase-rotation testing avoids crossing the test probes
  • Low input current helps avoid unintentional disconnection of RCD, RCBO and safety-breaker protected circuits
  • Single-pole phase testing provides an additional voltage-indication function
  • Automatic power control switches the tester on when a supported signal is detected
  • Integrated LED torch supports work in poorly lit environments
  • Self-test function checks that the batteries can power the tester correctly
  • CAT IV 1000 V rating and IP64 protection support use within the stated conditions

Common Applications

The Megger TPT420 is suitable for a range of electrical testing tasks, including:

  • AC voltage measurement
  • DC voltage measurement
  • Continuity testing
  • Testing within electrical installations
  • Automotive electrical testing
  • Fire alarm system testing
  • Solar and PV system testing
General Specifications
Specification Details
Product type Two-pole voltage tester
Display 13 LEDs and four-digit LCD
Backlight Automatic
Polarity indication Automatic LED indication for AC, positive DC and negative DC
Voltage indication without batteries Voltage warning LED operates when dangerous voltage is present, including when the batteries are exhausted; this function must not be used for measurement
Acoustic indication Sounder accompanies voltage and continuity indication; voltage threshold is approximately 38 V AC or 100 V DC
Single-pole phase test 100 to 1000 V AC at 50/60 Hz
Rotation field test 170 to 1000 V AC at 50/60 Hz, with left and right rotary-field indication
Diode test Visual and acoustic indication according to diode orientation
Auto-power-on Activates when continuity, AC or DC voltage above approximately 10 V, or a live phase at L2 is detected; also activates through the torch button
Auto-power-off Approximately 5 seconds after no signal is detected; torch switches off after approximately 10 seconds
Self-test Continuity LED and continuous audible tone confirm sufficient battery power when the probe tips are shorted together
Peak current Is <3.5 mA at 1000 V
Input current <3.5 mA at 690 V AC
<6 mA at 1500 V DC
Electrical measurement category CAT IV 1000 V
Safety standards IEC/EN 61243-3 and DIN VDE 0682-401
EMC standard EN 61326-1
Ingress protection IP64
Pollution degree 2
Power supply 2 x 1.5 V AAA batteries, IEC R03

Measurement and Accuracy Specifications
Measurement Function Range and Resolution Accuracy
AC voltage Range: 12 to 1000 V AC
Resolution: 1 V
Frequency range: 40 to 400 Hz
±3% ±5 dgt
DC voltage Range: 12 to 1500 V DC
Resolution: 1 V
Polarity: DC(±)
±3% ±5 dgt
LED voltage indication Nominal voltages: ±12, 24, 50, 120, 230, 400, 690 and 1000 V
Response time: <1 s at 100% of each nominal voltage
LED tolerances according to EN 61243-3
Continuity 0 to 500 kΩ
Visual and acoustic indication
No continuity measurement on the LCD
Threshold tolerance: +50%

Mechanical and General Information
Specification Details
Dimensions 67 mm (W) x 205 mm (L) x 19 mm (D)
Weight 180 g
Probe lead length 1.2 m
Operating temperature -5 to 40 °C, with no condensation
Storage temperature -20 to 70 °C, with no condensation
Humidity Maximum 85% RH
Maximum altitude Up to 2000 m
Probe features Main probe, remote probe, hand barriers, GS38 UK tips and Euro tips
Measurement light Integrated LED torch

Specification Notes
  • Datasheet specifications are stated at 23 °C ±5 °C and ≤80% RH
  • Measurement duty is 30 seconds on followed by a 240-second recovery period
  • Single-pole phase testing must not be the sole verification of a live circuit, and effective phase-rotation results require a three-phase four-wire system

TPT240 Documents

TPT240 Data Sheet

TPT240 User Guide

 

What’s Included
  • Protective pouch, 2005-536
  • GS38 probe-tip shrouds
  • 2 x AAA batteries