Fluke 1662 Datasheet (Size: 1 MB)

Fluke 1662 Manual (Size: 7 MB)

Fluke: Basic Electrical Installation Testing (Size: 609 KB)
Available for orders over £100
Apply for a credit account
Free gifts and exclusive benefits
Elevate your skills with us
For all orders over £100
Professional support
On many products
Enjoy Exclusive Benefits
Elevate Your Skills
Spend over £100 on any new goods order and receive automatic free shipping
Points make purchases! For every £1 spent, earn back 1p that can be spent on any future new goods purchase
We offer a Price Match Promise! Find an equivalent tester for a cheaper price on a competitor site, and we’ll do our best to match it
Make a new goods purchase with us, and receive a calibration discount voucher on your dispatch note when your item(s) are delivered
£569.00 (ex VAT)
Fluke 1662 UK Multifunction Installation Tester
The Fluke 1662 replaces the previous Fluke 1651 and 1652 multifunction testers and conforms to the latest 18th Edition Wiring Regulations.
This entry level model MFT from Fluke is solid and reliable, designed to meet the demands of every day testing and tests to all UK regulations. The Fluke 1662 is ideal for electricians and engineers both new and experienced, thanks to its easy to use, intuitive layout and ability to carry out all the basic testing procedures required in accordance to IEC 60364.
18th edition testing made easy
The Fluke 1662 makes everyday testing as simple as possible. It features an easy to use single click rotary dial to the right and large, central backlit LCD screen. The test and function buttons are to the left in order to create an uncluttered and simple to use interface. A remote test probe is also included as well as a mains zero adapter.
Adding to the improved usability, Fluke’s new ‘plug top’ style mains test lead allows you to plug all three leads into the Fluke 1662 in one go, saving you time and providing a secure connection. This simple feature was added to the 1660 range of MFT’s as a result of feedback from Fluke users over the years. A neck strap is also included for added comfort when testing for longer periods.
9 in 1 multifunction tester
The Fluke 1662 has all the functions you need for the essential testing of domestic, industrial and commercial electrical installations. The 1662 is also suitable for certifying fixed wiring in accordance with the requirements of IEC 60364 and relevant local standards.
True RMS AC/DC voltage and frequency measurements
Continuity measurement with auto-null feature
Insulation resistance testing
Polarity test
Phase sequence indicator
RCD testing
Loop testing
Prospective Fault Current (PFC)
Prospective Short Circuit (PSC)
Fluke 1662 vs 1663 vs 1664
1662 | 1663 | 1664 FC | |
Insulation-PreTest safety function NEW | ● | ||
Insulation test at L-N, L-PE, N-PE inputs NEW | ● | ||
Auto Test sequence NEW Performs line/loop impedance, RCD trip current/trip time and insulation tests in one go |
● | ||
Loop and line resistance—mΩ resolution | ● | ||
Continuity test at L-N, L-PE, N-PE inputs NEW | ● | ● | |
Continuity test selectable at 250mA/10mA with Auto polarity swap | ● | ● | ● |
Test smooth dc sensitive RCDs (Type B/B+) | ● | ● | |
Earth resistance | ● | ● | |
Voltage measurement TRMS (ac and dc) and frequency | ● | ● | ● |
Wiring polarity checker, detects broken PE and N wires | ● | ● | ● |
Insulation resistance | ● | ● | ● |
Continuity and resistance | ● | ● | ● |
Measure motor windings with continuity test (@ 10 mA) | ● | ● | ● |
Loop and line resistance | ● | ● | ● |
Prospective Earth Fault Current (PEFC/IK) | ● | ● | ● |
Prospective Short-Circuit Current (PSC/IK) | ● | ● | ● |
RCD trip time | ● | ● | ● |
RCD trip current (ramp test) | ● | ● | ● |
Measures trip time (ramp) and current for RCD type A and AC in one test | ● | ● | ● |
RCD variable test current | ● | ● | ● |
Automatic RCD test sequence | ● | ● | ● |
Phase sequence test | ● | ● | ● |
Other Features | |||
Fluke Connect compatibility NEW | ● | ||
ShareLive™ calling NEW | ● | ||
Fluke Cloud™ storage NEW | ● | ||
On/Off switchable Auto Start for RCD and Looptest NEW | ● | ● | ● |
Self-test | ● | ● | ● |
Illuminated display | ● | ● | ● |
Memory, interface | |||
Z Max memory (for loop tests- easy evaluation of the highest loop test value)NEW | ● | ● | |
Memory 3000 measurements | ● | ● | |
IR-USB and BLE interface (use with optional Fluke DMS software) | IR-USB | IR-USB/BLE | |
Included Accessories | |||
Heavy duty mains cord with single input connector NEW | ● | ● | ● |
Hard case | ● | ● | ● |
Fused test probes | ● | ● | ● |
Remote control probe | ● | ● | ● |
Zero adapter | ● | ● | ● |
Safety Overvoltage CAT III 500 V, CAT IV 300 V | ● | ● | ● |
3 year warranty | ● | ● | ● |
Insulation test voltages : 100V/250V/500V/1000V | ● | ● | |
Insulation test voltages : 50V/100V/250V/500V/1000V | ● |
Key Features
What’s Included
There are no reviews yet.
4 Century Road
High Carr Business Park
Newcastle-Under-Lyme
Staffordshire
ST5 7UG
01782 567 099
0800 040 7477
Registered address: Votec House, Hambridge Lane, Newbury, RG14 5TN, England. Copyright © 2023 UK Test Instruments Limited – All rights reserved.
Battery Producer Registration Number BPRN07695
WEEE Registration Number WEE/GF4998UZ