Megger MFT1711 Multifunction Tester

SKU: AVO/MFT1711
MPN: 1008-121
  • 250V, 500V and 1kV insulation testing
  • 2 and 3 wire non-trip loop testing
  • Auto RCD tests with ramp test function
  • TRMS voltage and frequency measurement

£663.00 (ex VAT)

£795.60 (inc VAT)

Earn 663 points

In Stock - Express Delivery Available

Why buy from Test4Less?

  • 250V, 500V and 1kV insulation testing
  • 2 and 3 wire non-trip loop testing
  • Auto RCD tests with ramp test function
  • TRMS voltage and frequency measurement
Free Shipping

Spend over £100 on any new goods order and receive automatic free shipping

Rewards

Points make purchases! For every £1 spent, earn back 1p that can be spent on any future new goods purchase

Our Price Promise

We offer a Price Match Promise! Find an equivalent tester for a cheaper price on a competitor site, and we’ll do our best to match it

Express Delivery & Calibration

Express Delivery is currently unavailable for customers wishing to add calibration to their New Goods order. For more information, visit our Delivery Information page. 

£663.00 (ex VAT)

£795.60 (inc VAT)

Earn 663 points

In Stock - Express Delivery Available

Customers also viewed

You may also like…

    • Megger MTB7671/2 Calibration Checkbox
      In Stock - Express Delivery Available

      Megger MTB7671/2 Calibration Checkbox

      £395.00 (ex VAT)
      £474.00 (inc VAT)
      • Ensures compliance with BS7671 and BS EN 61557 standards
      • Tests insulation, continuity, loop, PFC, and RCD functions
      • Provides clear Pass/Fail indications for test accuracy
      • Works with all testers for Part P certification verification
    • Megger MFT1721 Multifunction Tester
      In Stock - Express Delivery Available

      Megger MFT1721 Multifunction Tester

      £911.00 (ex VAT)
      £1,093.20 (inc VAT)
      • Designed for BS 7671 installation testing
      • Four insulation test voltages up to 1000 V
      • Supports Type B and three-phase RCD tests
      • Measures phase rotation and clamp current
    • Megger MFT-X1 Multifunction Tester
      In Stock - Express Delivery Available

      Megger MFT-X1 Multifunction Tester

      £1,319.00 (ex VAT)
      £1,582.80 (inc VAT)
      • In-built upgradability that ensures the tester is fully adaptable to future regulations
      • Full-colour screen and RCD configurator
      • Supports EVSE and solar applications
      • Easily removable, rechargeable battery pack
    • Kewtech KT65DL Digital 8-in-1 Multifunction Tester
      In Stock - Express Delivery Available

      Kewtech KT65DL Digital 8-in-1 Multifunction Tester

      £695.00 (ex VAT)
      £834.00 (inc VAT)
      • PAT testing function with download facility
      • Easy to use rotary dial, with twist and lock test button
      • Auto RCD test for 30mA RCD’s
      • Comprehensive test of A and AC type RCD’s
    • Fluke 1664FC Multifunction Installation Tester
      In Stock - Express Delivery Available

      Fluke 1664FC Multifunction Installation Tester

      £1,179.00 (ex VAT)
      £1,414.80 (inc VAT)
      • Automatically carries out 5 required installation tests in one sequence
      • Insulation PreTest prevents potentially serious and costly mistakes
      • FlukeCloud allows you to share your results
      • Test smooth DC sensitive RCDs (Type B/B+)
      This product has multiple variants. The options may be chosen on the product page
  • Designed for BS 7671 installation testing
  • Three insulation test voltages up to 1000 V
  • Two and three-wire non-trip loop testing
  • Auto and programmable RCD test functions

Megger MFT1711 Multifunction Tester

Built for electricians testing low-voltage electrical installations to BS 7671, the Megger MFT1711 Multifunction Tester supports certification work on domestic, commercial and industrial fixed wiring. It combines TRMS voltage and frequency measurement with 250 V, 500 V and 1000 V insulation testing, 200 mA continuity, loop impedance and prospective fault-current measurement, plus RCD testing. A large backlit display uses a digital/analogue arc and dual digital readout to show measurements with their relevant test parameters.

Two and three-wire non-trip loop modes support work on RCD-protected circuits, while the 2Hi range provides high-current phase-to-earth and phase-to-neutral measurements. Auto RCD testing runs its test sequence at 0° and 180°, with additional support for Type AC, A, S and programmable RCDs, 10 mA testing and ramp tests. Colour-coded rotary controls, automatic test starting, dual TEST and LOCK buttons, live-circuit warnings, a rubber overmould, IP54 protection and a 600 V CAT III or 300 V CAT IV rating support straightforward operation across demanding installation environments.

Key Benefits
  • Combines insulation, continuity, loop, RCD, voltage and frequency functions in one tester
  • Two and three-wire non-trip loop modes support measurements on RCD-protected circuits
  • Dual digital readouts show loop resistance and prospective fault current together
  • Auto RCD testing performs its sequence at 0° and 180° without further instrument operation
  • Automatic continuity testing leaves both hands available for holding the probes
  • Live-circuit detection displays the voltage and inhibits insulation testing above the permitted level
  • The backlit display presents measurements alongside relevant test parameters
  • TEST and LOCK buttons at both ends support left-handed and right-handed operation
  • Colour-coded rotary controls aid function and range selection
  • Rubber overmoulding and IP54 protection support operation in tough environments

Common Applications

The Megger MFT1711 Multifunction Tester is suitable for a range of low-voltage installation testing tasks, including:

  • BS 7671 electrical installation testing and certification
  • Domestic fixed wiring installation testing
  • Commercial fixed wiring installation testing
  • Industrial fixed wiring installation testing
  • Insulation resistance testing
  • Continuity and resistance testing
  • Earth loop impedance and prospective fault-current testing
  • Type AC, A, S and programmable RCD testing
  • TRMS supply voltage and frequency measurement

Why Choose This Model?

The MFT1711 suits electricians who require 250 V, 500 V and 1000 V insulation testing, 200 mA continuity, non-trip loop testing and Type AC, A, S and programmable RCD testing. Choose the MFT1721 when work additionally requires 100 V insulation testing, 15 mA continuity, phase-to-phase loop testing, R1 + R2, Type B or three-phase RCD testing, a 1000 mA RCD preset, phase rotation or clamp-current measurement.

Product Comparison
Feature Megger MFT1711 Megger MFT1721
Insulation test voltages 250 V, 500 V and 1000 V 100 V, 250 V, 500 V and 1000 V
Continuity test currents 200 mA 15 mA and 200 mA
Phase-to-phase loop testing Not supported 50 V to 500 V
R1 + R2 value Not supported Supported
RCD types Type AC, A, S and programmable Type AC, A, S, B and programmable
Three-phase RCD testing Not supported Supported without an earth connection
1000 mA RCD preset Not available Available
Phase rotation Not supported L1-L2-L3 and L1-L3-L2 indication
Clamp-current measurement Not supported Supported with the optional MCC1010 clamp
SP5 switched probe included Not included Included

General Specifications
Specification Details
Product type Multifunction tester for low-voltage electrical installations
Model and order code MFT1711-BS, 1008-121
Supported installations Domestic, commercial and industrial fixed wiring installations
Display Backlit display with dual digital readout and digital/analogue arc
Controls Colour-coded rotary switches with TEST and LOCK buttons at both ends
Automatic test start Automatic continuity testing with selectable loop and RCD auto-start functions
Insulation test voltages 250 V, 500 V and 1000 V
Continuity test current 200 mA
Continuity buzzer thresholds 0.5 Ω, 1 Ω, 2 Ω, 5 Ω, 10 Ω, 50 Ω and 100 Ω
Loop test modes 3Lo three-wire non-trip, 2Lo two-wire non-trip and 2Hi two-wire high current
Loop result display Loop resistance and prospective fault current displayed simultaneously
Loop functions Z, ZMAX, PFC and PSCC
RCD types Type AC, A, S and programmable RCDs
RCD test functions 1/2 x I, 1 x I, 5 x I, ramp and Auto testing at 0° and 180°
RCD presets 10 mA, 30 mA, 100 mA, 300 mA and 500 mA
Input protection Protection against live circuits up to 600 V during insulation testing, including when the test is locked on
Fuse type 2 x F2 1000 V 30 kA fuses
Ingress protection IP54
Installation category 600 V CAT III / 300 V CAT IV, maximum phase-to-phase voltage 550 V
Safety standards BS EN 61010-1:2010 and BS EN 61010-30:2010
Measurement standard IEC 61557:2007 parts 1 to 10
EMC IEC 61326 edition 2, Class B locations
Power supply 6 x 1.5 V IEC LR6 type AA alkaline cells or 6 x 1.2 V NiMH HR6 rechargeable cells

Measurement and Accuracy Specifications
Measurement Function Range and Resolution Accuracy
TRMS voltage 10 V to 600 V Intrinsic accuracy: ±2% ±1 V
Maximum service error: ±5% ±2 digits
Frequency 15 Hz to 400 Hz
Resolution: 0.1 Hz
Intrinsic accuracy: ±0.5% ±2 digits
Maximum service error: ±5% ±3 digits
1000 V insulation resistance 10 kΩ to 999 MΩ ±3% ±2 digits
500 V insulation resistance 10 kΩ to 500 MΩ
Greater than 500 MΩ
10 kΩ to 500 MΩ: ±3% ±2 digits
Greater than 500 MΩ: ±10% ±4 digits
250 V insulation resistance 10 kΩ to 250 MΩ
Greater than 250 MΩ
10 kΩ to 250 MΩ: ±3% ±2 digits
Greater than 250 MΩ: ±10% ±4 digits
Insulation test output Short-circuit current: 1.5 mA nominal
Test current on load: ≥1 mA at minimum insulation pass values
Output voltage: -0% +20% at rated load or less
Voltage display: ±3% ±3 digits ±0.5% of rated voltage
Continuity and resistance 0.01 Ω to 99.9 Ω
100 Ω to 99.9 kΩ
Open-circuit voltage: 5 V ±1 V
Test current: >200 mA at ≤2 Ω
0.01 Ω to 99.9 Ω: ±2% ±2 digits
100 Ω to 99.9 kΩ: ±5% ±2 digits
Maximum service error: ±12% ±2 digits
2Hi loop test L-PE and L-N
Display range: 0.01 Ω to 1000 Ω
Supply: 48 V to 280 V, 45 Hz to 65 Hz
Test current: 4.0 A at 230 V
PSCC range: 20 kA
Intrinsic accuracy: ±5% ±3 digits
Maximum service error: ±10% ±2 digits
3Lo and 2Lo loop test L-E display range: 0.01 Ω to 1000 Ω
Supply: 48 V to 280 V, 45 Hz to 65 Hz
Test current: pulsed
PFC range: 20 kA
0.01 Ω to 39.9 Ω: ±5% ±5 digits
40.0 Ω to 999 Ω: ±10% ±5 digits
Maximum service error: ±10% ±2 digits
RCD testing Supply: 48 V to 280 V, 45 Hz to 65 Hz
No-trip test: 1/2 x I
Trip tests: 1 x I and 5 x I
Auto and ramp testing
No-trip current: -10% to 0%
Trip current: +0% to +10%
Ramp test current: ±5% ±1 digit
Trip time: ±1% ±1 ms
Maximum service error: ±10% ±2 digits
Programmable RCD 10 mA to 50 mA: 1 mA steps
50 mA to 500 mA: 5 mA steps
500 mA to 1000 mA: 10 mA steps
Maximum service error: ±10% ±2 digits
Touch voltage 0 V to 253 V +5% +15% ±0.5 V

Mechanical and General Information
Specification Details
Operating temperature -10 °C to +55 °C
Storage temperature -25 °C to +70 °C
Humidity 90% R.H. at +40 °C maximum
Maximum altitude 2000 m to full safety specification
Dimensions 150 mm high x 85 mm wide x 235 mm deep
Weight 1000 g ±10%, including batteries but excluding test leads, accessories and carry case
Case protection Rubber overmould for protection and grip
Operating positions Handheld, floor standing, placed on a ladder shelf or platform, or suspended around the neck
Automatic power off Selectable 2-minute or 20-minute inactivity period
Backlight duration 20 seconds in manual mode, with selectable automatic mode

Specification Notes
  • Insulation testing is inhibited when circuit voltage exceeds 50 V, with a warning displayed above 25 V
  • Loop and RCD tests require a supply between 48 V and 280 V at 45 Hz to 65 Hz
  • Phase-to-phase loop testing and phase-rotation indication are not available on the MFT1711

Meta Description

Megger MFT1711 Multifunction Tester supports BS 7671 testing with 1 kV insulation, non-trip loop and Auto RCD functions.

Reviews

There are no reviews yet.

Be the first to review “Megger MFT1711 Multifunction Tester”
Megger MFT1711 Multifunction Tester

Built for electricians testing low-voltage electrical installations to BS 7671, the Megger MFT1711 Multifunction Tester supports certification work on domestic, commercial and industrial fixed wiring. It combines TRMS voltage and frequency measurement, 250 V, 500 V and 1000 V insulation testing, 200 mA continuity testing, earth loop impedance measurement and RCD testing. A large backlit display uses dual digital readouts and a digital analogue arc to present measurements and test parameters.

Loop functions include two and three-wire non-trip testing for RCD-protected circuits, with loop resistance and prospective fault current shown together and PFC or PSCC measurement up to 20 kA. For circuit protection testing, the instrument supports Type AC, A, S and programmable RCDs, alongside Auto, ramp and 10 mA test options. Colour-coded controls, test and lock buttons at both ends, a rubber overmould, IP54 protection and 600 V CAT III or 300 V CAT IV ratings support operation across demanding installation environments.

Key Benefits
  • Combines voltage, insulation, continuity, loop and RCD testing in one instrument
  • Two and three-wire non-trip loop modes support testing on RCD-protected circuits
  • Dual readouts display loop resistance and prospective fault current together
  • Auto RCD testing runs the test sequence at 0° and 180° without further instrument operation
  • Automatic test starting leaves both hands available for holding the probes
  • Live-circuit detection displays the voltage and inhibits insulation testing above the permitted level
  • The backlit display presents two measurement values or a value and its test parameter simultaneously
  • Test and lock buttons at both ends support left-handed and right-handed operation
  • Colour-coded rotary controls aid function and range selection
  • Rubber overmoulding and IP54 protection support use in tough environments

Common Applications

The Megger MFT1711 Multifunction Tester is suitable for a range of low-voltage installation testing tasks, including:

  • BS 7671 electrical installation testing
  • Domestic fixed wiring certification
  • Commercial fixed wiring certification
  • Industrial fixed wiring certification
  • Insulation resistance testing
  • Continuity and resistance testing
  • Earth loop impedance and prospective fault current testing
  • Type AC, A, S and programmable RCD testing
  • TRMS supply voltage and frequency measurement
Why Choose This Model?

The MFT1711 is suited to electricians who need the essential tests required for BS 7671 electrical certification without Type B or three-phase RCD testing, phase rotation, 100 V insulation testing or current measurement. It combines 250 V, 500 V and 1000 V insulation testing, 200 mA continuity, non-trip loop testing, Auto RCD functions and TRMS voltage measurement in an IP54 instrument.

Product Comparison
Feature Megger MFT1711 Megger MFT1721
Insulation test voltages 250 V, 500 V and 1000 V 100 V, 250 V, 500 V and 1000 V
Continuity test currents 200 mA 15 mA and 200 mA
Phase-to-phase loop testing Not supported 50 V to 500 V
R1 + R2 value Not supported Supported
RCD types Type AC, A, S and programmable Type AC, A, S, B and programmable
Three-phase RCD testing Not supported Supported without an earth connection
1000 mA RCD preset Not available Available
Phase rotation Not supported L1-L2-L3 and L1-L3-L2 indication
Clamp-current measurement Not supported Supported with the optional MCC1010 clamp
SP5 switched probe included Not included Included
General Specifications
Specification Details
Product type Multifunction tester for low-voltage electrical installations
Model and order code MFT1711-BS, 1008-121
Supported installations Domestic, commercial and industrial fixed wiring installations
Display Backlit display with dual digital readout and digital analogue arc
Controls Colour-coded rotary switches with test and lock buttons at both ends
Automatic test start Can start testing without pressing the TEST button
Insulation test voltages 250 V, 500 V and 1000 V
Continuity test current 200 mA
Continuity buzzer thresholds 0.5 Ω, 1 Ω, 2 Ω, 5 Ω, 10 Ω, 50 Ω and 100 Ω
Loop test modes 3Lo three-wire non-trip, 2Lo two-wire non-trip and 2Hi two-wire high current
Loop result display Loop resistance and prospective fault current
Loop functions PFC, PSCC, Z and ZMAX
RCD types Type AC, A, S and programmable RCDs
RCD test functions 1/2 x I, 1 x I, 5 x I, ramp and Auto testing at 0° and 180°
RCD presets 10 mA, 30 mA, 100 mA, 300 mA and 500 mA
Input protection Protection against live circuits up to 600 V during insulation testing, including when the test is locked on
Ingress protection IP54
Installation category 600 V CAT III / 300 V CAT IV, maximum phase-to-phase voltage 550 V
Safety standards BS EN 61010-1:2010 and BS EN 61010-30:2010
Measurement standard IEC 61557:2007 parts 1 to 10
EMC IEC 61326 edition 2, Class B locations
Power supply 6 x IEC LR6 type AA alkaline cells or 6 x 1.2 V NiMH rechargeable cells

Measurement and Accuracy Specifications
Measurement Function Range and Resolution Accuracy
TRMS voltage 10 V to 600 V Intrinsic accuracy: ±2% ±1 V
Maximum service error: ±5% ±2 digits
Frequency 15 Hz to 400 Hz
Resolution: 0.1 Hz
Intrinsic accuracy: ±0.5% ±2 digits
Maximum service error: ±5% ±3 digits
1000 V insulation resistance 10 kΩ to 999 MΩ ±3% ±2 digits
500 V insulation resistance 10 kΩ to 500 MΩ
Greater than 500 MΩ
10 kΩ to 500 MΩ: ±3% ±2 digits
Greater than 500 MΩ: ±10% ±4 digits
250 V insulation resistance 10 kΩ to 250 MΩ
Greater than 250 MΩ
10 kΩ to 250 MΩ: ±3% ±2 digits
Greater than 250 MΩ: ±10% ±4 digits
Insulation test output Short-circuit current: 1.5 mA nominal
Test current on load: ≥1 mA at minimum insulation pass values
Output voltage: -0% +20% at rated load or less
Voltage display: ±3% ±3 digits ±0.5% of rated voltage
Continuity and resistance 0.01 Ω to 99.9 Ω
100 Ω to 99.9 kΩ
Open-circuit voltage: 5 V ±1 V
Test current: >200 mA at ≤2 Ω
0.01 Ω to 99.9 Ω: ±2% ±2 digits
100 Ω to 99.9 kΩ: ±5% ±2 digits
2Hi loop test Display range: 0.01 Ω to 1000 Ω
Supply: 48 V to 280 V, 45 Hz to 65 Hz
Test current: 4.0 A at 230 V
PSCC range: 20 kA
Intrinsic accuracy: ±5% ±3 digits
Maximum service error: ±10% ±2 digits
3Lo and 2Lo loop test Display range: 0.01 Ω to 1000 Ω
Supply: 48 V to 280 V, 45 Hz to 65 Hz
Test current: pulsed
PFC range: 20 kA
0.01 Ω to 39.9 Ω: ±5% ±5 digits
40.0 Ω to 999 Ω: ±10% ±5 digits
RCD testing Supply: 48 V to 280 V, 45 Hz to 65 Hz
No-trip test: 1/2 x I
Trip tests: 1 x I and 5 x I
Auto and ramp testing
No-trip current: -10% to 0%
Trip current: +0% to +10%
Ramp test current: ±5% ±1 digit
Trip time: ±1% ±1 ms
Programmable RCD 10 mA to 50 mA: 1 mA steps
50 mA to 500 mA: 5 mA steps
500 mA to 1000 mA: 10 mA steps
Maximum service error: ±10% ±2 digits
Touch voltage 0 V to 253 V +5% +15% ±0.5 V

Mechanical and General Information
Specification Details
Operating temperature -10 °C to +55 °C
Storage temperature -25 °C to +70 °C
Humidity 90% R.H. at +40 °C maximum
Maximum altitude 2000 m to full safety specification
Dimensions 150 mm high x 85 mm wide x 235 mm deep
Weight 1000 g ±10%, including batteries but excluding test leads, accessories and carry case
Case protection Rubber overmould for protection and grip
Operating positions Handheld, floor standing, placed on a ladder shelf or platform, or suspended around the neck

Specification Notes
  • Insulation testing is inhibited when circuit voltage exceeds 50 V, with a warning displayed at 25 V
  • Loop and RCD tests require a supply between 48 V and 280 V at 45 Hz to 65 Hz
  • Phase-to-phase loop testing and phase-rotation indication are not available on the MFT1711

What’s Included
  • Megger MFT1711-BS Multifunction Tester, 1008-121
  • Robust moulded carry case
  • Quick start guide
  • Calibration certificate
  • Megger embroidered neck strap, 2001-509
  • 3-wire lead set with prods and clips, 1001-991
  • Mains plug test lead, BS1363, 6220-810
  • 6 x IEC LR6 type AA alkaline cells

Reviews

There are no reviews yet.

Be the first to review “Megger MFT1711 Multifunction Tester”

Ask a question

Ask a question | Product pages