Welcome to Test4Less

FREE SHIPPING

Available for orders over £100

CREDIT ACCOUNT

Apply for a credit account

GIFTS & REWARDS

Free gifts and exclusive benefits

TRAINING COURSES

Elevate your skills with us

ON SALE

Exclusive offers, shop today

FREE SHIPPING

For all orders over £100

CHAT | EMAIL | PHONE

Professional support

FREE GIFTS

On many products

CUSTOMER REWARDS

Enjoy Exclusive Benefits

BOOK YOUR TRAINING

Elevate Your Skills

Megger PAT150R Rechargeable PAT Tester

SKU AVO/PAT150R Categories , ,
  • Test group pass limits and test duration can be configured by the user.
  • Bond lead resistance can be nulled to reduce measurement errors.
  • Live circuit measurement is available for testing the mains supply and socket polarity or electrical circuit voltage to 300 V ac.
  • Can be used for testing fixed appliances
Free Shipping

Spend over £100 on any new goods order and receive automatic free shipping

Rewards

Points make purchases! For every £1 spent, earn back 1p that can be spent on any future new goods purchase

Our Price Promise

We offer a Price Match Promise! Find an equivalent tester for a cheaper price on a competitor site, and we’ll do our best to match it

Express Delivery & Calibration

Express Delivery is currently unavailable for customers wishing to add calibration to their New Goods order. For more information, visit our Delivery Information page. 

£634.09 (ex VAT)

£760.91 (inc VAT)

Earn 634 points

Usually Ships In 3 to 5 Business Days
pdf
pdf

Reviews

There are no reviews yet.

Be the first to review “Megger PAT150R Rechargeable PAT Tester”

Megger PAT150R Rechargeable PAT Tester

The PAT100 series of hand help portable appliance testers enable simple, fast safety testing in all environments including offices, shops and business units. It is ideally suited to training organisations with a very short learning curve and tough, reliable functionality. With rubber armoured cases and fitted with hardened, scratch proof glass, the PAT100s are exceptionally tough instruments.

Battery powered operation makes the PAT100s perfect for those locations where an electrical supply is not available, inconvenient or unsafe, especially building sites and warehouses. The PAT100 series conforms to all UK and European requirements for electrical safety testing.

Test groups

Test groups enable the correct sequence of tests to be performed automatically with minimum intervention by the user. This keeps testing simple, reduces test times to a minimum and helps to prevent testing errors.

PAT120:

  • The PAT120 model has test groups available for Class I, Class II and Extension/Power leads.
  • Fixed PASS limits.
  • Insulation testing at 500 V (default) or 250 V can be selected at the start of the test.
  • Leakage testing uses a “Substitute Leakage” also known as the “Alternative” method to remove the need for a mains supply during test.


The PAT150:

  • The PAT150 has additional tests available for testing portable RCDs (PRCDs) of 10 mA and 30 mA.
  • Separate tests for Continuity, Insulation, mains powered leakage testing and SELV measurements can be made using the Quick Test (QT) button.
  • Test group pass limits and test duration can be configured by the user.
  • Bond lead resistance can be nulled to reduce measurement errors.
  • Live circuit measurement is available for testing the mains supply and socket polarity or electrical circuit voltage to 300 V ac.
  • Can be used for testing fixed appliances.


PAT150R:

  • Rechargeable version of the PAT150

Key Features

  • Simple Tick/Cross, pass/fail indication plus measurement
  • Battery powered with rechargeable options
  • Includes 250 V Insulation and Leakage testing for safe IT testing and surge protected devices
  • Testing portable and fixed electrical equipment
  • 10 mA and 30 mA Portable RCD lead testing (PAT150)
  • Adjustable PASS test limits (PAT150)
  • Substitute and Mains powered leakage testing (PAT150)
  • Tough, rubber armoured with built-in front cover, hardened, scratch proof display window


Continuity test.

Used for measuring the proper bonding of all metal parts of a class I device to the protective conductor. Tests are performed at 200 mA dc in both polarities to be compliant with international and UK regulation or recommendations. This test is safe to perform on equipment where higher test currents could cause damage.

Insulation testing.

Used for measuring the separation of conductive parts or conductors from earth. This test is usually performed at 500 V dc. The PAT100 series maintain the necessary test voltage down to 0.5 Mohms.

What’s Included

  • Megger PAT150
  • Continuity/earth bond lead
  • SELV/mains voltage test lead Red x1
  • Extension lead adaptor BS1363
  • Mains plug test lead
  • AC Mains charger
  • Carry case
  • Manufacturers calibration certificate

QUESTIONS

Product Question
Name
Name
Plain text only. HTML is not allowed.

REVIEWS

Write Your Own Review

Reviews

There are no reviews yet.

Be the first to review “Megger PAT150R Rechargeable PAT Tester”

Related Products

You may also like…